Laserfiche WebLink
SAN 10 A Q U I N Environmental Health Department <br /> -- C (DUN Y <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name : Facility Address: Date: <br /> YRC INC 1 1535 E Pescadero Ave, Tracy February 13 , 2020 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I, CLASS II, or MINOR - Notice to Comply) <br /> Item # Remarks <br /> 211 CCR 2715(c) (2) No employee present that were trained in the operation and maintenance of the UST system by a <br /> DO . <br /> OBSERVATION : The designated operator employee training for Derek Whitten was initially performed on 7/24/ 19 , <br /> but is listed as having responsibility as a facility employee as of 11 /19/18 . <br /> REGULATION GUIDANCE : The designated operator shall train facility employees in the proper operation and <br /> maintenance of the UST system at least once every 12 months . The training shall be conducted before the <br /> individual performs the duties of a facility employees . The training shall include , but is not limited to : <br /> 1 . Operation of the UST system in a manner consistent with the facility's best management practices <br /> 2 . Employee's role with regard to monitoring equipment as specified in the facility's monitoring plan <br /> 3. Employee's role with regard to spills and overfills as specified in the facility's response plan <br /> 4. Name of the contact person (s) for emergencies and monitoring equipment alarms <br /> Initial training shall also include a site-specific practical demonstration that provides both sharing information and <br /> evaluating knowledge for responding to emergencies , leak detection , monitoring alarms , spills and overfills . At least <br /> one of the facility employees present during operating hours shall have current training . <br /> CORRECTIVE ACTION : Ensure that employees have been trained by the designated operator prior to assuming <br /> responsibility as a facility employee . <br /> This is a minor violation . <br /> 319 CCR 2635 , 2637 . 11 2665 , 2712 No spill bucket, failed to contain 5 gallons , no means to keep it empty , or failed to be <br /> tested . <br /> OBSERVATION : The 1 , 000 gallon used oil UST is not equipped with a spill container. <br /> REGULATION GUIDANCE : All USTs shall be equipped with a spill container that collects any hazardous <br /> substances spilled during delivery operations , that has a minimum capacity of five gallons and a drain valve that <br /> allows drainage of the collected spill into the primary container or provide a means to keep the container empty. <br /> CORRECTIVE ACTION : Immediately contact a properly licensed , trained , and certified contractor to install an <br /> approved spill container under permit and inspection of the EHD . If a spill container can 't be installed immediately , <br /> there is a possibility that the UST system may be red tagged to prevent fuel inputs . <br /> OBSERVATION : The soap spill container failed when tested . <br /> REGULATION GUIDANCE : All spill containers shall have a minimum capacity of five gallons and be capable of <br /> containing a spill or overfill until it is detected or cleaned up . <br /> CORRECTIVE ACTION : Immediately contact a properly licensed , trained , and certified contractor to repair or <br /> replace the spill container under permit and inspection of the EHD . <br /> This is a Class II violation . <br /> Overall Inspection Comments . <br /> FA0003854 PR0232495 SCO01 02/13/2020 <br /> EHD 23-01 Rev. 9/20/2019 Page 5 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 T 209 468-3420 1 F 209 464-0138 1 www. sjcehd . com <br />