Laserfiche WebLink
Working To Restore Nature <br /> Addendum One to Remedial Action Plan March 1, 1993 <br /> Coca-Cola Former Distribution Facility, Stockton, California 54006.01 <br /> ' schedule will be made if additional requirements are specified by the guidelines set forth <br /> by the Air District in the Permit to Construct or the Permit to Operate for this site, as <br /> necessary. <br /> System Sampling <br /> ' Typical SJVUAPCD guidelines require that during the startup phase of each proposed <br /> abatement device, influent and effluent air samples to the VES will be taken daily for the <br /> first three days of operation to demonstrate system efficiency, and every two weeks <br /> thereafter for the next one month after which sample collection will be performed once <br /> every month for the life of the remediation system. With the exception of influent and <br /> effluent air samples collected and analyzed as detailed above, during the first two days of <br /> operation and later on a biweekly and monthly basis, all other sampling of the VES wall be <br /> conducted using a field organic vapor monitoring instrument approved by the SJVUAPCD <br /> If at any time the results of laboratory analyses or field monitoring readings show emission <br /> limits to be exceeded, a confirmation air sample will be taken immediately and analyzed on <br /> a 24 hour turnaround basis. If emission limits are still exceeded, the system will be shut <br /> down and any necessary corrective action will be performed before repeating the startup <br /> sequence. The SJVUAPCD will be notified that emission limits were exceeded within 24 <br />' hours of such indication. Any additional sampling required by the Operating Permits will <br /> be incorporated into the sampling plan after the Permits have been issued. <br /> Task II.-- System Startup Report <br /> This task is a performance evaluation and is required as part of the SJVUAPCD Permit to <br /> Operate. This task is a brief report summarizing the construction, and the results of the air <br /> sampling and startup testing, and will be submitted to Coca-Cola and the SJVUAPCD after <br />' the SJVUAPCD inspection and after the laboratory results are received. <br /> This report may document the following- hours of operation; system influent and effluent <br />' field monitoring readings collected; laboratory results of influent and effluent air samples <br /> collected and analyzed;total and individual vapor extraction well flow rates; induced vacuum <br /> responses recorded in observation wells; all other relevant field data collected; and results <br />' obtained such as observed radius of influence, and system treatment efficiency using the <br /> thermal oxidizer. <br />' 13 <br />