Laserfiche WebLink
Working To Restore Nature <br /> 1 Addendum One to Remedial Action Plan March 1, 1993 <br /> Coca-Cola Former Distribution Facility, Stockton, California 54006.01 <br /> ' Task 12. Operations. Maintenance and Compliance Monitoring and Re ortin <br /> 1 After the first month of operation, site visits will be made at a minimum once every two <br /> weeks for the remainder of the life of the remediation system. Modifications to this typical <br /> schedule will be made if additional requirements are specified by the guidelines set forth <br /> ' by the SJVUAPCD in the Authority to Construct and the Permit to Operate for this site. <br /> Monthly self-momtonng reports, or as required by SJVUAPCD Permit to Operate, detailing <br /> all field and laboratory data collected and results, as well as recommendations if needed, <br /> ' will be submitted for the life of the soil remediation system. <br /> Site operations and monitoring will include- monitoring and adjustment of system <br /> ' parameters to optimize VES extraction, treatment, and site cleanup efficiency; periodic <br /> sampling and field monitoring of influent and effluent as required by the SJVUAPCD, other <br /> periodic maintenance procedures, including inspection and cleaning of all lines, process <br /> ' equipment, ensuring that the continuous measuring temperature, flow, pressure, and other <br /> recording instrumentation are functional, etc. Parameters monitored and adjusted in the <br /> field will include- field measurement of vapor extraction flowrates, induced vacuum <br /> responses at onsite wells, and hydrocarbon vapor concentrations measured with an organic <br /> vapor monitor approved by the SJVUAPCD. <br /> A remote monitoring system will be installed to continuously monitor and periodically report <br /> the process variables which can influence the systems' performance and cause an alarm <br /> condition. The monitoring system will also notify RESNA's Stockton office when an alarm <br />' condition exists so that the condition can be rectified prior to restart of the system The <br /> remote monitoring system will report the process and system data to RESNA's Stockton <br /> office on a daily basis <br /> If at an time the results of laboratory atony analyses or field monitoring readings show air <br /> enussion limits to be exceeded, a confirmation air sample will be collected immediately and <br /> analyzed on a 24 hour turnaround basis. If emission limits are still exceeded, the system will <br /> be shut down and any necessary corrective action will be performed before repeating the <br /> startup sequence The SJVUAPCD will be notified that regulatory limits were exceeded <br /> within 24 hours of such indication. Any additional sampling required by the Operating <br /> Permits will be incorporated into the sampling plan after the Permits have been issued <br />' PROPOSED SCHEDULE OF WORK <br /> The preliminary schedule for the proposed scope of work is summarized in Plate 8, and <br /> briefly discussed here The Task 1 Vapor Extraction Test is completed (RESNA, January <br /> 14 <br />