Laserfiche WebLink
0 <br /> Coca-Cola Enterprises - West <br /> USTEC Job No 90054 03 <br /> o Exhaust stack temperature above 650° Fahrenheit <br /> o Loss of process airflow. <br /> o Loss of compressed air pressure <br /> o LEL levels in the process gas above 28% <br /> o High bed back-pressure. <br /> o High water level in knock-out pot <br /> Instrumentation includes thermocouples with values that are visible through a data access panel <br /> The center bed thermocouple is connected to a strip chart recorder to show maintenance of bed <br /> temperature above 1,800° Fahrenheit <br /> 5 411 Additional Eguil2ment <br /> Ip Other components include an air compressor, knock-out pot, air solenoid valves, air silencers, <br /> compressed air filters and regulators, and pressure switches <br /> 5.4.12 Thermal Oxidizer <br /> The thermal oxidizer used with the vapor extraction system will operate 24 hours a day, and is <br /> designed to maintain a bed temperature of no less than 1,800° Fahrenheit at which point <br /> destruction efficiency is no less than 95% <br />