My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2020
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
N
>
99 (STATE ROUTE 99)
>
4733
>
2300 - Underground Storage Tank Program
>
PR0232510
>
COMPLIANCE INFO_2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2024 1:51:15 PM
Creation date
6/23/2020 4:29:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2020
RECORD_ID
PR0232510
PE
2361
FACILITY_ID
FA0003924
FACILITY_NAME
HUNT & SONS INC - ARCH ROAD CARDLOCK
STREET_NUMBER
4733
Direction
S
STREET_NAME
STATE ROUTE 99
City
STOCKTON
Zip
95206
APN
17930008
CURRENT_STATUS
01
SITE_LOCATION
4733 S HWY 99
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
59
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN Environmental Health Department <br /> Underground Storage Tank Program Inspection Report% : <br /> Facility Name: Facility Address: Date: <br /> ER Vine Stockton % 4733 S HWY 99 , STOCKTON June 24 , 2020 <br /> lJSTSystem-Observations i <br /> 314 HSC 25290. 11 25290.23 Failed to have secondary containment or secondary containment not tight o V ❑ R ❑ COS <br /> 25291 <br /> 315 HSC 25291 (e) Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003) ■ V ® R ® COS <br /> 316 HSC 25290.t (c3), Secondary containment not constructed to prevent water intrusion (after Jul 2003) ❑ V ❑ R ❑ COS <br /> 25290.2(03 <br /> 317 CCR 2636, 2643(0)(1), Line leak detector (LLD) not installed ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 318 CCR 2666(0), 2643(0) Leak detector failed to detect a 3.0 gallons per hour leak at 10 pounds per square inch e V ❑ R ■ COS <br /> (1) <br /> 3191OR 2635, 2637.11 No spill bucket, failed to contain 5 gallons, no means to keep it empty, or failed to be tas d ® V ❑ R ❑ COS <br /> C27121 <br /> 320 CCR 2635, 2637.21 Failure to comply with the Installation, Inspection, or record keeping of A overfill prevention D V ❑ R ❑ COS <br /> 2665, 2712 <br /> 321 CCR 2635(0)(1) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 322 HSC 25281 .6(a) Unburied below grade emergency generator system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 323 HSC 25283.5(a) Unburied below grade UST system failed to meet exemption status ❑ V ❑ R ❑ COS <br /> 324 CCR 2717. 1 (g) Tampered with red tag ❑ V ❑ R ❑ COS <br /> 325 CCR 2717. 1 (f), Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST ❑ V ❑ R ❑ COS <br /> 25292.3(0 <br /> 326 HSC 25299(a)(9) Tampered with or disabled leak detection devices or alarms ❑ V ❑ R ❑ COS <br /> 327 CCR 2631 .1 , 2660(m) UST system not compatible with the substance stored o V ❑ R ❑ COS <br /> 328 HSC 25298 Failed to comply with temporary closure requirements in V ❑ R ❑ COS <br /> 329 HSC 25298; CCR 2670, Failed to comply with all permanent closure requirements ❑ V a R ❑ COS <br /> 2672 <br /> 330 CCR 2636((), 2666(0)7 No LLD on the emergency generator that restricts or shuts off the flow or triggers an alarm ❑ V ❑ R o COS <br /> 2666(f) <br /> 331 CCR 2630(d), 2641 (a) Liquid does not flow into the sump in the event of a leak (i.e., failure to remove test boot), o V in R ❑ COS <br /> 332 CCR 2631 (b&d), Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> 2666(b&e <br /> 333 CCR 2635, 2636(b), Failure to comply with the cathodic protection system requirements ❑ V n R o COS <br /> 2662, 2712 <br /> 334 CCR 2666(b)(2) Single-walled pipe not upgraded to double-walled interstitially monitored pipe during repair ❑ V ❑ R ❑ COS <br /> 335 CCR 2630, 2632, 2643, Equipment or methods used to monitor the UST system are not certified by an Independent third-party ❑ V ❑ R ❑ COS <br /> 2644. 1 <br /> 336 HSC 25292.3(c)(1)(C) Owner/operator allowed dispensing from a UST that has a red lag affixed to the fill pipe ❑ V ❑ R ❑ COS <br /> Single-Wallgd Non-Pressurized Piping <br /> 401 CCR 2636(a)(3), Suction piping not properly sloped or incorrectly located check valve ❑ V D R o COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring / maintain records for single-walled conventional suction (pre-1984) ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d), 2661 (f) Failure to conduct 0.1 gph test for single-walled conventional suction systems (pre-Jan 1984) ❑ V D R o COS <br /> 404 CCR 2843(e), 2661 (f) 0.1 -gph line test for single-walled gravity piping not performed biennialy or post repair (pre-1984) ❑ V ❑ R ❑ COS <br /> Otfierviolaflons , <br /> FA0003924 PR0232510 Scoot 06/24/2020 <br /> EHD 23-01 Rev. 9/20/2019 Page 3 of 6 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.