My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1989-2001
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_1989-2001
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/13/2022 2:55:50 PM
Creation date
6/23/2020 6:37:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1989-2001
RECORD_ID
PR0231952
PE
2351
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
01
SITE_LOCATION
2905 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231952_2905 W BENJAMIN HOLT_1989-2001.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
490
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN C Y PUBLIC HEALTH SERVICES/ENVIRONMENTAL HEA IVISION <br /> I UGST WORKSHEET FOR SITE CLOSURE EVALUATION DATE <br /> NAME OF FACILITY SWEEPS CODE <br /> ADDRESS TANK ID T <br /> TANK SIZE FUEL TYPE <br /> II. GENERAL SITE HISTORY <br /> *** <br /> Is permit current? Yes No Permit # - Facility Status Code Doc.Soit/GW Cont Yes No <br /> Number of Tanks at facility Age of Tanks(if available) Type of Tank Steel Fbrgl Sngl Dual <br /> III. TANK HISTORY <br /> Was Tank tested? Yes No Failed precision test ? Yes No If yes, give dates) <br /> Was a repair made to the tank system? Yes No If yes, what was repaired? <br /> Was repair done under inspection? Yes No Were soil samples analyzed? Yes No BTXE TPH-G TPH-D Pb/EDB <br /> Type of failure/discharge catastroic tong-term leakage overfill unknown other: <br /> IV. REMOVAL HISTORY (ATTACH INSPECTION REPORT FOR SITE DETAILS/COLLECT DATA FOR LEACHING POTENTIAL ANALYSIS) <br /> Soil Samples Received Yes No Depth to Ground Water Ref/Year ; Average Annual Precipitation A= 14 10-25 <br /> On-Site Wells) Yes No Number & TypeIrr Dan Pub <br /> S Score S Score S Score <br /> Distance to Wetl(s) from Tank ft; ft; ft C 10 pts C 9 pts C 5 pts <br /> 0 if 0 if 0 if <br /> R condition R condition R condition <br /> V. Site Feature - Leaching Potential Analysis E is met E is net E is met <br /> Minimum Depth to groundwater from the Soil Sample (feet) >100 51-100 25-50\1 <br /> Fractures in subsurface (applies to foothills or mountain areas) None Unknown Present <br /> Average Annual Precipitation (inches) xxxxxx <10 9 10-25 xxxxxxx 26-40\2 <br /> Man-Made conduits which increase vertical migration <br /> of leachate (i.e., septic systems, water wells, ponds) None Unknown Present <br /> Unique site features: Recharge area, coarse soil, nearby wells. At least More than <br /> xxxxxx None one one <br /> COLUMN TOTALS>>>TOTAL POINTS + + = <br /> Sample Result: (B T X OR E) RANGE OF TOTAL POINTS 49 pts or more 41 - 48 pts 40 pts or less <br /> B T X E B T X E <br /> MAXIMUM ALLOWABLE B-T-X-E LEVELS (PPM) 1 50 50 50 .3 .3 1. 1. NA\3 <br /> Sample Result: GASOLINE 1000 100 10 <br /> MAXIMUM ALLOWABLE TPN LEVELS (PPM) <br /> TPH DIESEL 10,000 1000 100 <br /> FOOTNOTES: ***If documented soil and/or ground water contamination is present, do not complete the leaching potential <br /> analysis. (i.e., site is currently on UGT Contamination List for soil or ground water.) <br /> \1 If depth is > 5 ft. and < 25 ft., score 0 points. If depth <=5 ft., do not use table. <br /> \2 If precipitation is > 40 inches, score 0 points. <br /> \3 Levels for BTX&E are not applicable at a TPH concentration of 10 ppm (gasoline) or 100 ppm (diesel). <br /> VI. STAFF RECOMMENDATION/CONCLUSION <br /> 1. Are 8TX & E or TPH Concentrations > Allowable Levels *Yes No <br /> 2. Recommend Site Closure Yes No *If Yes, Refer to Site Mitigation for Evaluation <br /> VII. REVIEW EVALUATION - TO BE COMPLETED BY A SUPERVISOR/SENIOR <br /> CONCUR WITH STAFF RECOMMENDATION FOR CLOSURE YES NO REFERRED TO SITE MITIGATION FOR EVALUATION YES NO <br /> DATE REFERRED / / DATE CLOSURE LETTER MAILED <br /> NAME OF <br /> EVALUATOR <br /> EH 23 80 (UGTWKSHT)\5/90 <br />
The URL can be used to link to this page
Your browser does not support the video tag.