My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2022 4:23:07 PM
Creation date
6/23/2020 6:38:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010
RECORD_ID
PR0231952
PE
2351
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
01
SITE_LOCATION
2905 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231952_2905 W BENJAMIN HOLT_2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FOLLOW THE CORRECT ORDER: _ -- <br /> A) FIELD AIR INTEGRITY TEST <br /> B) MANDATORY HYDROSTATIC FILLING P I <br /> C) ADVANCED LEAK DETECTION PROCEDURE <br /> D) ATTACHING YOUR MANOMETER <br /> i <br /> A FIELD AIR INTEGRITY TEST <br /> THIS TEST MUST BE COMPLETED 3 <br /> PRIOR TO THE HYDROSTATIC °;" <br /> FILLING OF THE DOUBLEWALL <br /> ''j <br /> PRODUCT. <br /> A.1 - Use test assembly and pressure sump to no more <br /> than 4 PSI. Close off with ball valve and resume other work. Allow 1 Hour before recording pressure. <br /> Field Air Integrity Inspection Test : <br /> BRAVO Hold pressure for a minimum of 1 hour for a Field Integrity Inspection Test. <br /> QUALITY The Tank Sump PASSES the integrity test if the Sump shows NO signs of <br /> STANDARD continuous pressure decay. <br /> A.2 - IF TEST PASSES - CONTINUE ON TO THE HYDROSTATIC FILL & ALD PROCEDURE, <br /> outlined in STEP B. <br /> 11h 0 IS. Bravo Systems Highly Recommends <br /> M <br /> an Extended pressure test. <br /> Ensure that the penetration fittings that are being used <br /> with the Vacuum Monitored System can withstand the <br /> amount of Vacuum your Monitoring System will generate. <br /> 3 ii-ALDP-D-AB-2007 <br />
The URL can be used to link to this page
Your browser does not support the video tag.