My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2905
>
2300 - Underground Storage Tank Program
>
PR0231952
>
COMPLIANCE INFO_2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/15/2022 4:23:07 PM
Creation date
6/23/2020 6:38:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010
RECORD_ID
PR0231952
PE
2351
FACILITY_ID
FA0003712
FACILITY_NAME
CHEVRON STATION #94275*
STREET_NUMBER
2905
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09760004
CURRENT_STATUS
01
SITE_LOCATION
2905 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0231952_2905 W BENJAMIN HOLT_2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
03 <br /> Testing Procedure <br /> The following guide line in intended to verify the successful installation of the SEBEF fitting.An <br /> official test might be required in accordance with local regulations. <br /> Suitable Testing Criteria are: <br /> • Dry Fluid Pressure Test—Compressed air, Nitrogen, Helium are the allowed Gaseous Materials. <br /> •Wet Fluid Pressure Test—Filling Fluid Sump Compatible or Water, No Brine(saline) is allowed. <br /> •Hydrostatic Test— Filling Fluid Sump Compatible or Water, No Brine(saline) is allowed. <br /> •Vacuum Test <br /> TIP: By Choosing a testing Protocol it is possible to verify the leak free installation and experience <br /> the system operating pressure/vacuum rates. <br /> Hydrostatic test: The system will be tested using the a selected liquid fluid at a pressure resulting <br /> from the Hydrostatic effect over the system. In case a repair in required, drain the fluid and remove <br /> possible greasy residuals. <br /> Pressure Test: Utilizing pressure will enhance the testing purpose.At the same time a better <br /> strength simulation can be performed. Using Liquid fluids, drain and cleaning procedure are involved <br /> whenever a repair is needed.A Pressure test is suggested to locate possible leaks visually. <br /> Vacuum: Same as the pressure Test with the only difference that it is not possible to visually locate <br /> a possible leak. <br /> Before run the test be sure that the condition listed below are in place: <br /> •Adhesive materials curing time elapsed. <br /> •The secondary pipe has been already properly scraped,wiped with Acetone and inserted <br /> in to the SEBEF fitting already installed as per description onto this manual. <br /> ATTENTION:Make sure that both reducers are in position before begin any welding. <br /> •Because of the fitting purpose, be advised that the pressure test will involve all the parts <br /> connected to the SEBEF Annulus. Make sure that all the openings, test ports, drainages, <br /> are properly plugged, sealed or closed before and during the testing period. <br /> •Because of the same reason above, MAKE SURE that no other testing protocols require <br /> lower pressure. By not respecting this criteria, serious damages can occur to other system <br /> components. The use of a pressure reducer valve is strongly suggested for a better <br /> pressure control. <br /> NOTE:Use ONLY tubin_a.fittings, ball valves,gapes that are proven leak free and properly <br /> sized. <br /> By not respectina this condition a consistent risk to collect false results mlaht come along. <br />
The URL can be used to link to this page
Your browser does not support the video tag.