My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/11/2024 3:15:22 PM
Creation date
6/23/2020 6:39:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
395
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB JUNE 2008 <br /> Monitorins Re uirements of Double-walled Piping Installed On or After Jul 1, 2004 <br /> M 20 111 <br /> • The entire piping length, including piping • The interstitial space between the primary • The single-walled transition pipe or <br /> within sumps or UDC's, must be monitored containment(i.e., single-walled transition pipe or fill fill piping must be contained within a <br /> using vacuum, pressure, or interstitial liquid piping) and secondary containment (i.e., sump or double-walled sump and/or double- <br /> level measurement methods; UDC) must be continuously monitored using walled UDC that either: extends to the <br /> vacuum or pressure; surface, or has a double-walled <br /> AND product tight lid that is continuously <br /> • Sumps and UDC's require sensors AND monitored using vacuum, pressure, or <br /> capable of detecting liquid and vapor • No sensors in sumps and UDC's required; interstitial liquid level measurement <br /> releases from the primary containment; methods; <br /> AND <br /> AND • 3.0 gph LLD for pressurized piping. AND <br /> • 3.0 gph LLD for pressurized piping. • Sumps and UDC's required to have <br /> sensors that are capable of detecting <br /> liquid releases; <br /> AND <br /> • 3.0 gph LLD for pressurized piping. <br /> HSC 25290.1 HSC 25290.1 HSC 25290.1 <br /> Enhanced Leak Detection ELD Testing <br /> IT el <br /> 09 <br /> pgy <br /> " M r.- <br /> Y <br /> Enhanced leak detection testing must be Must conduct testing every three years. Must conduct a one-time test. <br /> conducted if notified by the State Water <br /> Resources Control Board, and are located <br /> within 1000 feet of a public drinking water <br /> well. <br /> Page 7 of 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.