Laserfiche WebLink
Matrix of Nonmetallic Pipe Monitoring Applications <br /> Gravity Flow, Vacuum (V), Pressure (P), and Interstitial Liquid Level Monitoring (ILLM) <br /> (Enclosure to State Water Board letter dated February 29, 2008; Matrix Updated September 30, 2009) <br /> om MINNIE=MIN <br /> Secondary Containment Fuels6 ®Ren Closed <br /> Brand Type and Size (min. 5 psi rating on SC per UL) (min.. 50 psi rating on SC per UL) <br /> (Coaxial reported as ID of PS; <br /> SOS reported as OD of SC) Gravity Flow or Vacuum,Pressure,or . <br /> Ambient ILLM Pressurized ILLM <br /> Ameron <br /> Dualoy 3000/1L Rigid; SOS; 3"&4" MV,CT,HB,AM Gravity Flow V, P <br /> Rigid; SOS; 6" MV,CT,HB,AM Gravity Flow None <br /> Dualoy 3000/LCX Rigid; Coaxial(sticks); 2"&3" MV,CT,HB,AM Gravity Flow,AILLM' V, P, PILLM' <br /> Rigid; Coaxial(sticks);4" MV,CT,HB,AM Gravity Flow,AILLM' None <br /> Franklin Fueling/APT <br /> XP-150-SC Flexible; Coaxial(coil); 11/2" MV,CT,HB,AM Gravity Flow V <br /> XP-100 175 200 Flexible;Coaxial coil • 1" 13/4" &2" MV,CT,HB,AM Gravity Flow None <br /> NUPI <br /> Smartflex Flexible; Coaxial(coil); 2", 21/2",&5" MV,CT,HB,AM Gravity Flow V, P <br /> Flexible; Coaxial sticks • 2" 4"&5" MV,CT,HB,AM Gravity Flow V P <br /> OPW-FCS <br /> C15,C20,C30 Flexible;Coaxial(coil); 11/2", 2",&3" MV,AM Gravity Flow None <br /> C75,C104 Flexible; Coaxial(coil); 3/4"&1" MV,AM Gravity Flow V, P <br /> PGFC-21505 Flexible; Coaxial coil • 11/2 MV,AM Gravity Flow V P <br /> PetroTechnik <br /> UPP Flexible; Coaxial(coil); 11/2", 2" MV,CT,HB,AM Gravity Flow V, P <br /> Flexible;Coaxial sticks • 1'/2" 2" 3" 4" MV,CT,HB,AM Gravity Flow V P <br /> NOV Fiber Glass Systems <br /> Red Thread IIA Rigid; SOS; 3"&4" MV,CT,HB,AM Gravity Flow V, P <br /> Rigid; SOS; 6" MV,CT,HB,AM Gravity Flow None <br /> Western Fiberglass <br /> Co-Flex Flexible; Coaxial(coil); 11/2", 2",&3" MV,AM Gravity Flow,AILLMZ None <br /> Co-Flex4 Flexible; Coaxial(coil); 3/4"&1" MV,AM Gravity Flow,AILLMZ V, P, PILL <br /> MZ <br /> Co-Flex3 Flexible; Coaxial coil • 11/2" MV,AM Gravity Flow AILLMZ V P PILLMZ <br /> 1. Use only with Ameron's Brine Filled Interstitial Space Monitoring System(limited to maximum length of 344 feet). <br /> 2. Use only with Western Fiberglass Co-Flow Hydraulic Interstitial Monitoring System(limited to maximum length of 200 feet). <br /> 3. Procedures to verify the appropriate pipe for V or P applications include inspection in the field for a date stamp equal to or after November 30,2006,and a marking of"50 PSI"on <br /> the secondary containment. <br /> 4. Procedures to verify the appropriate pipe for V and P applications include inspection in the field for a date stamp equal to or after January 29,2008 and a marking of 50 PSI"on the <br /> secondary containment. <br /> 5. Procedures to verify the appropriate pipe for V or P applications include inspection in the field for a date stamp equal to or after November 16,2006,and a marking of"50 PSI"on <br /> the secondary containment. <br /> 6. E85 is covered within the CT fuels testing range;therefore only pipe with the Cr fuels marking can store E85. <br />