My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2024 4:04:53 PM
Creation date
6/23/2020 6:39:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2013-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
407
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ma r. 27. 2013 8:33AM No. 6553 P. 3 <br /> AppenOlx VC <br /> C?NITRiNG SYSTEM CERTIFICATION <br /> For Use ByAff Jurisdictions Within the State of California <br /> Authority cited.Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23,California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for <br /> each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the lank system <br /> owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems Wlhin 30 days of test date. <br /> A. General information <br /> Factlity.Narne; Costco#1091 . Bldg.No..2880 <br /> Silo Address: 2680 Reynolds Ranch, City. Lodi CA, Zjp: 95240 <br /> Facility Contact Person: Manager Contact Phone No..{__) <br /> MakelModet of Monitoring System:VEEDER ROOT TLS-350 Dale of Tesfing/ServUrig:�� 2 D 1 3 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the a2propriato boos to indicates ecWcul mr;rnt Ins (edlfserviceri: <br /> FAnnufar <br /> ADDITIVE VENT aox Tank to: GAS VENT BOX. <br /> Gauging Probe. Model: In-Tank Gauging Probe, Model: <br /> Space or Vauq Sensor. Model: Annular Space or Vault Sensor. Model: <br /> ump/Trench Sensor(s). Model:AoaiW�.77A9 323xrtar9-M Piping Sump t Trench Sensor(s). Modal:p Sensor(s). Model: Fill Sump Sensor(s). Model; <br /> ical Line Leak Detector. Modal: Mechanical Line Leak Detector. Model, <br /> lr Electronic Line Leak Detector, Model: Electronic Line Leak Detector. Model: <br /> x Tank Overfill/High-Level Sensor. Model: Tank Overfill/High-Level Sensor, Model: <br /> Other(Specify e u men[Igo and modol—in E on Pane 2). Others cit a ui ant I e and mope[in Section E on P e z. <br /> Tank ID: Tank ID: NIA <br /> In-Tank Gauging Probe. Modal: in-Tank Gauging Probe. Model WA <br /> Annular Space or Vault Sensor. Model: Annular Space or Vaull Sensor. Model: NIA <br /> Piping Sump i Trench Sensoria), Model: Piping Sump/Trench Sensor(s). Model, NIA <br /> Fill Sump Sonsor(s). Model. _ Fill Sump Sonsor(s). Madel: WA <br /> Mechanical Line Leak Detector. Modal: Mechanical Line Leak Detector. Modal, NIA <br /> Electronic Line Leak Detector. Model_ Electronic tine Leak Detector. Model: NiA <br /> Tank Overfill 1 High-Level Sensor. Model: Tank Overfill/Hlgh-Level Sensor. Model: NIA <br /> Other wcl =m"t Igo and modol in Section E on Page 2. Other a ci a u( mens type and model in S bon E Page 2). <br /> Dispenser ID; 13-14 Dlapenser BD: 15-16 <br /> Dispenser Containment Sensor(6), Model:I843eo-323 w!Hvd� Dispenser Containment Sensor(s). Model: 923 wt Hvdro-3iM <br /> Shear Velve(s). Shear Valve(s). <br /> Dts anssr Containment Flost s and Chain(s). Dis neer ntalnmam Floats and Ghain s. <br /> Dispenser to: Dispenser ID; <br /> Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model: <br /> Shear Valve(s). Shear Vatve(s). <br /> Diap2nper Containment Float(s) and Chains. Dispenser Contathmsnt Floats and Chains. <br /> DlspenserID; Dlspenserla: <br /> Dispenser Containment Sensor(s). Model: Dispenser Containment Sensor(s). Model; <br /> Shear Vaive(s). Shear Velvets). <br /> Dispenser Containment FloAjW and Ghat Dfagenlor Containment Floats and Chains. <br /> 'If the facility contains more tanks or dispensers,copy this form, include information for every tank and dispenser at the facility. <br /> C. Cerilflcadon.- I carilly that the equlpinint Identltted•In this document was Inspectediserviced In accordance with the manufacturers, <br /> guidelines. Attached to this Certification to informellon(e.g.manufacturers'cheokllsle)necessary to verity that this information Is correct <br /> end a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generahrmg such reports,i have also attached a <br /> copy of the report;(chock ell that appal: x System set-up d Alarm history report <br /> m G$eit. <br /> Technician Name(print): Edwin Coreas. Signature: <br /> Certification No.: B34020 License,No.: 804431 <br /> Testing Company Name: Jones Covey Group,Inc. Phone No.; 8S( 8 ) 872-7581 <br /> Testing Company Address: 9595 Lucas Ranch Rd.9100 Rancho Cucamonga CA 91730 Date of Testing/Servicing.3/47 i 2 0 1 3 <br /> Monitoring System Certification Page of 12107 <br />
The URL can be used to link to this page
Your browser does not support the video tag.