My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
R
>
REYNOLDS RANCH
>
2680
>
2300 - Underground Storage Tank Program
>
PR0535432
>
COMPLIANCE INFO_2013-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/12/2024 4:04:53 PM
Creation date
6/23/2020 6:39:39 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2015
RECORD_ID
PR0535432
PE
2351
FACILITY_ID
FA0020431
FACILITY_NAME
COSTCO WHOLESALE #1091
STREET_NUMBER
2680
STREET_NAME
REYNOLDS RANCH
STREET_TYPE
PKWY
City
LODI
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
2680 REYNOLDS RANCH PKWY
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2351_PR0535432_2680 REYNOLDS RANCH_2013-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
407
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mar, 27. 2013 8;33AM No, 6553 P. 4 <br /> D. aesulte of restingfServicing <br /> software version installed: 330,01 <br /> Complete the followlna checklist: <br /> it Yes No Is the audible alarm operational? <br /> x Yes No' Is the visual alarm operational? <br /> x Yea No' Were all sensors vlsuai Ins ectad funodonaty tested,and confirmed o rational? <br /> x Yes No' Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their <br /> Proper operation? <br /> W_ Yes No' If alarms are relayed to a remote monitoring afalion,to all communications equipment(e.g.modem)operallonal? <br /> NIA <br /> x Yes No' For pressurized piping systems,6009 the turbine automatically shut down if the piping secondary oontainmenl monitoring system <br /> N/A detects a leak,fails to operate,or Is eleotrleally dlsohnnected? II yea=which sensors Initiate positive shut-down? (Check ak that apply) <br /> ®Sump/Ranch Sensors; MWspenser Containment Sensors. Did you confirm positive shul-down due to leaks AW sensor <br /> fatlureldisconneotion? ®Yes; QNo. <br /> if Yes No' For tank systems that utilize the monitoring system as the primary tank overfill warning dQvme(Le,no mechanical overfill prevention <br /> NIA valve Is installed),Is the overfill warning alarm visible and audible at the lank fill poirn(s)and operating property? Ifea,at what percent <br /> of tank capacity does the alarm td er7 90,,,_% <br /> LXYG <br /> x o Was any monitoring equipment replaced? I yes, Identity specific sensors, probes, or other equipment replaced and list the <br /> manufacturer name and model for alt re la enl pans In Section E below. <br /> x No Was liquid found Inside any secondary containment systems designed as dry systems? (Check a#that apply)OProducl; awater. tf <br /> es describe causes in Section E.below. <br /> Not Was monitoring system set-u reviewed to ensure proper settings?Ad c sat up reports,H applicable <br /> Not Is all monitoring equipment operational per manuraclurer a epecilioalions? <br /> In Sect cit below,describe how and when these deficiencies were or will be corrected. <br /> L Comments: <br /> Monitoring System Cartifteatlan Page of 12107 <br />