Laserfiche WebLink
ro <br /> Ma r. 27, 2013 8:33AM No. 6553 P. 6 <br /> I. Results of Vacuum/Pressure Monitoring Equipment Testing <br /> This page should be-used to document testing and servicing of vacuum and pressure interstitial sensors.A copy of this form must <br /> be included with the Monitoring System Certification Form, which must be provided to the tank system owner/operator. The <br /> owner/operator must submit a copy of the Monitoring System Certification Form to the local agency regulating UST systems <br /> within 30 days of test date, <br /> VEEDER-ROOT TLS-350 Model: 332117-001 system Type:o pressure;m vacuum <br /> LL <br /> S-9 Cornponent(s)Monitored by this Sensor, S-9 UNLEADED 87(A)PRODUCT LINE. <br /> Sensor Functionality Test Result:ZI Pass; 0 Fail Interstitial Communication Test Result: Pass; ❑ Fail <br /> 8-10 Component($)Monitored by this Sensor; 8-10 UNLEADED 87(A)VAPOR LINE. <br /> Sensor Functionality Test Result:®Pass, E] Fail Interstitial Communication Test Result: Pass; ❑ Fail <br /> 8-11 Component(s)Monitored by this Sensor: S-I I UNLEADED 97(A)VENT LM. <br /> Sensor Functionality Test Result:9fl Pass; El Fall Interstitial Communication Test Result: Pass; ❑ Fail <br /> S-12 Component(s)Monitored by this Sensor: 8.12 UNLEADED 87(B)PRODUCT LINE. <br /> Sensor Functionality Test Result:N Pass; El Fail Interstitial Communication Test Result: Pass; ❑ Fail <br /> S-13 Component(s)Monitored by this Sensor: S-13 UNLEADED 87(8)SIPN. <br /> Sensor Functionality Test Result:go Pass, 0 Fall Interstitial Communication Test Result: Pass; ❑ Fail <br /> S-17 Component(s)Monitored by this Sensor: S-17 PREMIUM PRODUCT LINE. <br /> Sensor Functionality Test Result:91 Pass; [I Pail Interstitial Communication Test Result: Pass; ❑ Fail <br /> B-18 Component(s)Monitored by this Sensor: S-18 PREMIUM VENT LINE <br /> Sensor Functionality Teat Result:IM Pass, D Pail Interstitial Communication Test Result: Pass; ❑ Fail <br /> 5-23 Component(s)Monitored by this Sensor, S-23 ADDETIVE LINE <br /> Sensor Functionality Test Result:29 Pass; [I Fail Interstitial Communication Test Result: Pass; ❑ Fail <br /> S-24 Component(s)Monitored by this Sensor; S-24 ADDETIVE ENT <br /> Sensor Functionality Test Result;M]Pass; E] Fail Interstitial Communication Test Result,IM Pass; E] Fall <br /> 8-14 Component(s)Monitored by this Sensor: S-14 87(B)VENTLM <br /> Sensor Functionality Test Result:IM Pass; n Fail Interstitial Communication Test Result:NPass; El Fail <br /> How was interstitial communication verified? <br /> Leak Introduced at Far End of Interstitial Space;' El Gauge, 0 Visual Inspection; El Other(Describe in See.J <br /> below) <br /> Was vacuum/pressure restored to operating levels in A interstitial spaces? ID Yes [3 No(Ifw,describe in See,J,below) <br /> J. Comment$(500 characters max.use additional sheets it needed): <br /> If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br /> sensor,vacuum/pressure has been demonstrated to be Communicating throughout the interstice. <br /> Pnge 4 of_ <br />