2705
>
2300 - Underground Storage Tank Program
>
PR0231072
>
COMPLIANCE INFO_1995-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/23/2023 3:13:14 PM
Creation date
6/23/2020 6:40:25 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1995-2006
RECORD_ID
PR0231072
PE
2361
FACILITY_ID
FA0002048
FACILITY_NAME
TESORO (SPEEDWAY) 68221
STREET_NUMBER
2705
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
APN
12121008
CURRENT_STATUS
01
SITE_LOCATION
2705 COUNTRY CLUB BLVD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231072_2705 COUNTRY CLUB_1995-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
426
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Monitoring Plan-Page 2 . <br /> C. Pipeline Monitoring <br /> Line monitoring is performed using the following methods: (Check all which apply) <br /> ® Continuous electronic monitoring of piping sumps)/trench and other secondary containment low points. <br /> Leak Sensor Manufacturer: Veeder Root Model No.: 794380-208 <br /> Will a piping leak alarm trigger automatic shutdown of the pump(i.e. turbine)? ® Yes; ❑No. <br /> Will failureldisconnection of monitoring system trigger automatic shutdown of pump? ❑ Yes; ®No. <br /> ® Mechanical line leak detector(MLLD) that routinely performs 3.0 g.p.h. leak tests and restricts or shuts off <br /> product flow when a leak is detected. <br /> MLLD Manufacturer: Red Jacket,Vaporless Model No.: FXI,LD2000 <br /> ❑ Electronic line leak detector(ELLD)that routinely performs 3.0 g.p.h. leak tests. <br /> ELLDManufacturer: Model No.: <br /> Programmed line tightness tests: ❑ Minimum Monthly 0.2 g.p.h.; ❑ Minimum Annual 0.1 g.p.h. <br /> Will ELLD detection of a piping leak trigger automatic shutdown of the pump? Q Yes; ❑No. <br /> Will failure or disconnection of the ELLD trigger automatic shutdown of the pump? ❑ Yes; ❑No. <br /> ® Line tightness testing conducted: ® Annually; ❑ Every 3 years; ❑ Other(spec): <br /> ❑No product or remote-fill piping is connected to the UST(s). <br /> ❑ Piping is suction piping meeting all requirements for exemption from monitoring. [See 23 CCR§2636(a)(3)1 <br /> ❑ Other(specify): <br /> D. Dispenser Leak Detection: (Check all which apply) <br /> ❑No dispensers in system. <br /> ® Float and chain assembly in under-dispenser containment trips shear valve in case of leak. <br /> Assembly Manufacturer: Unknown Model No.: <br /> ❑ Continuous electronic monitoring of under-dispenser containment. <br /> Leak Sensor Manufacturer: Model No.: <br /> Will a leak trigger audible and visual alarms? ❑ Yes; ❑No. <br /> Will a leak alarm trigger automatic shutdown of the pump? ❑ Yes; ❑No. <br /> Will failure/disconnection of monitoring system trigger automatic shutdown of pump? ❑ Yes; ❑No. <br /> ❑ Dispenser housings are opened and fittings inside are visually inspected daily for leaks (required if under- <br /> dispenser containment is not installed). <br /> ❑ Other(specify): <br /> E. Monitoring Locations <br /> Included with this monitoring plan is a Site Plan which shows the general tank and piping layouts and the <br /> locations where monitoring is performed(i.e. locations of sensors, line leak detectors, control panels, etc.). <br />
The URL can be used to link to this page
Your browser does not support the video tag.