My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
2057
>
2300 - Underground Storage Tank Program
>
PR0231083
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/4/2020 11:55:06 AM
Creation date
6/23/2020 6:41:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231083
PE
2361
FACILITY_ID
FA0003735
FACILITY_NAME
QUICK N EASY MART
STREET_NUMBER
2057
Direction
S
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16515309
CURRENT_STATUS
01
SITE_LOCATION
2057 S EL DORADO ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231083_2057 S EL DORADO_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
299
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AdML <br /> San Joaquin County <br /> Environmental Health Department x . <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> _ Murk ti <br /> orag pection FFp y <br /> , <br /> Facility Name: Facility Address: Date: <br /> QUICK N EASY MART 2057 S EL DORADO ST, STOCKTON February 09, 2017 <br /> Ni <br /> r�SiteRecords' <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site V ■R ❑COS <br /> 205 CCR 2712(i) Failure to have an approved UST response plan available onsite V ■R ❑COS <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions 71 V ❑R ❑COS <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment D V ❑R ❑COS <br /> 208 CCR 2650(e) Failed to notify the EHD of a reportable unauthorized release D V ❑R ❑COS <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed r V ❑R ❑COS <br /> 210 CCR 2715(e) Designated operator monthly inspection reports not maintained on site for at least 12 months ■V ■R ❑COS <br /> 211 CCR 2715(f) Designated operator employee training not performed or log not kept V ■R ❑COS <br /> 212 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD V ❑R ❑COS <br /> 213 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept ❑V ❑R ❑COS <br /> 214 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept V ❑R ❑COS <br /> �k� ; c ii JMi �"`M1 ,rr <br /> o = t)S`6 s flbei�i <br /> 301 HSC 25292.1 UST system is not operated to prevent unauthorized release,including spills and overfills V ❑R ❑COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) V ❑R ❑COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) ❑V ❑R ❑COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) D V ❑R ❑COS <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained V ❑R ❑COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity V ❑R ❑COS <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained ❑V ❑R ❑COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm Ei V ❑R ❑COS <br /> 309 CCR 2636(f)(1) Monitoring in sump/UDC failed to activate an audible and visual alarm or stop the flow product o V ❑R ❑COS <br /> 310 CCR 2636(f)(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs o V ❑R ❑COS <br /> 311 CCR 2638(a),26410) Failed to properly program or operate leak detection equipment V ❑R ❑COS <br /> 312 CCR 2638(f) Failed to affix a tag sticker on monitoring equipment certified, repaired,or replaced V ❑R ❑COS <br /> 313 HSC 25290.1,25290.2, Failure to construct,operate,and maintain primary containment as product-tight V ❑R ❑COS <br /> 25291 <br /> 314 HSC 25290.1,25290.2, Failed to have secondary containment or secondary containment not tight Ei V ❑R ❑COS <br /> 25291 <br /> 315 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) V ❑R ■COS <br /> 316 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion(after Jul 2003) o V ❑R ❑COS <br /> 25290.2(c3) <br /> 317 CCR 2636(f)(2) Line leak detector not installed ❑V ❑R ❑COS <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi V ❑R ❑COS <br /> 319 CCR 2635(b) No spill bucket,failed to contain five gallons,or failed to provide a means to keep it empty V ❑R ❑COS <br /> 320 CCR 2635(b)(2) Overfill prevention system not present or failed to meet overfill requirements V ❑R ❑COS <br /> 321 CCR 2635(b)(2) Overfill prevention was overridden ❑V ❑R ❑COS <br /> Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.