11 <br />ISD Floyv Meter Installation Guide Seal and Connect Field Wiring <br />1. Seal wire nuts with epoxy sealant following the instructions in Figure 5. <br />t <br />(f'") <br />ID Epoxy sealant is irritating to eyes, respiratory system, and skin. Can cause allergic skin reaction. <br />Contains: epoxy resin and Cycloaliphatic epoxycarboxylate. Precautions: Wear suitable protective clothing, <br />gloves, eye, and face protection. Use only in well ventilated areas. Wash thoroughly before eating, drinking, or <br />smoking. <br />e --- — <br />1. � � •' <br />Instructions: <br />NOTE: When temperature is below 50°F (10'C), keep resin in <br />a warm place prior to mixing (e.g., in an inside pocket next <br />to body). <br />1. Open epoxy sealant package, and remove resin pak. <br />2. Holding resin pak as shown in A, bend pak along long <br />length. <br />3. As shown in B, firmly squeeze the RED SIDE of the resin, <br />forcing it through the center seal and into BLACK SIDE. <br />AM From probe, <br />sensor, or Elk <br />transduIcerTo console <br />Make sure that <br />the ends of cable <br />sheathing are sub- <br />merged in sealantwrap <br />e nuts <br />4. Mix thoroughly to a uniform color by squeezing contents <br />back and forth 25-30 times. <br />5. Squeeze mixed, warm resin into one end of bag and cutoff <br />other end. <br />6. Slowly insert wiring connections into sealing pack until they <br />fit snugly against the opposite end as shown in C. <br />7. Twist open end of bag and use tie wrap to close it off and <br />position the tie wrapped end up until the resin jells. <br />conW.3 eo=v2� ws <br />Figre 5 fpjsealindeld wiring <br />2. Push the epoxy sealed bag into the junction box. Replace and tighten the junction box cover. <br />3. Terminate field wiring into TLS Console and connect to Smart Sensor Module located in the intrinsically safe <br />wiring compartment of the TLS as shown in Figure 6. Note: you must observe polarity! Also, the cable length <br />between the console and sensor must not exceed the distance stated in the TLS•3XX Site Prep manual (P/N <br />576013-879). <br />4. Replace the lower sheet metal doors in the dispenser. <br />Note: Intrinsically safe devices must be installed in accordance with Article 504 of the National Electrical <br />Code, ANSI/NFPA 70, for installation in the United States, or Section 18 of the Canadian Electrical Code for <br />installations in Canada. <br />This intrinsically safe flow meter P/N 331847.001, has only been evaluated for connection to a UL listed TLS - <br />350 Series Liquid Level Gauge / Leak Detector. <br />N <br />