EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
7906
>
2300 - Underground Storage Tank Program
>
PR0231094
>
COMPLIANCE INFO_2002-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2020 2:10:05 PM
Creation date
6/23/2020 6:42:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2005
RECORD_ID
PR0231094
PE
2361
FACILITY_ID
FA0003632
FACILITY_NAME
AJS MINI MART INC
STREET_NUMBER
7906
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
07935016
CURRENT_STATUS
01
SITE_LOCATION
7906 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231094_7906 N EL DORADO_2002-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pageof <br /> 8. FRISER CONTAINMENT SUMP TE*G <br /> Facility is Not Equipped With Fill Riser Containment Sums ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Tested ❑ <br /> Test Method Developed By: D Sump Manufacturer ®Industry Standard ❑Professional Engineer <br /> D Other(Specify) <br /> Test Method Used: ❑Pressure ❑ Vacuum ®Hydrostatic <br /> D Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Results Equipment Resolution: .0007" <br /> Sump# T-7_t Sump# y7- z Sump# 7- Sump# >/ <br /> rSumpD�ia!eter: y y" '�y" �/SS ": e " 6 2 " <br /> Sump Material: ,,_ ;l <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest „ <br /> Electrical Penetration: Z"� Z <br /> Condition of sump prior to testing: � .., <br /> Portion of Sump Tested 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST 2"ABOVE HIGHEST <br /> PENETRATION PENETRATION PENETRATION PENETRATION <br /> Wait time between applying water 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> and starting test: <br /> Test Start Time: 91`y2 <br /> Initial Readin (Rt): 1Z..D 27z 5 /®. 4623Y M-10340 v.• Y?.3' <br /> Test End Time: /o.- 23 F--5c. /v- z. <br /> Final Reading(RF): jzv7°7y/ /rs.C 75� z../v3 ry V,9-3;975"7 <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-Rt): _,9 zY -wool <br /> Pass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> =r -- <br /> 3 <br /> Is there a sensor in the sump? ®Yes D No D NA IN Yes D No D NA ®Yes D No D NA 19 Yes D No D NA <br /> Does sensor alarm when either ®Yes D No D NA ®Yes D No D NA 19 Yes D No D NA ®Yes D No D NA <br /> product or water is detected? <br /> Was sensor removed for Testing? IBJ Yes D No D NA ®Yes D No D NA ®Yes D No D NA ®Yes D No D NA <br /> Was sensor properly replaced and 0 Yes D No D NA ®Yes D No D NA ®Yes D No D NA .Yes D No ❑NA <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> BP Arco # 02130 <br /> 7906 N EI Dorado Street <br /> Stockton, CA 95210 <br /> N05431- SB 989 Testing <br />
The URL can be used to link to this page
Your browser does not support the video tag.