My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2005
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
E
>
EL DORADO
>
7906
>
2300 - Underground Storage Tank Program
>
PR0231094
>
COMPLIANCE INFO_2002-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/23/2020 2:10:05 PM
Creation date
6/23/2020 6:42:08 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2005
RECORD_ID
PR0231094
PE
2361
FACILITY_ID
FA0003632
FACILITY_NAME
AJS MINI MART INC
STREET_NUMBER
7906
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
07935016
CURRENT_STATUS
01
SITE_LOCATION
7906 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231094_7906 N EL DORADO_2002-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
298
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page V of 6 <br /> 7.UM&DISPENSER CONTAINMENT(UD TING <br /> Test Method Developed By: UDC Manufacturer D Industry Standard ® Professiona7Eng7ineer <br /> 711 <br /> Other(Specify) <br /> Test Method Used: Pressure D Vacuum D Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br /> IN <br /> Under-Dispenser Containment Number Below <br /> - <br /> UDC Manufacturer: <br /> UDC Material_- 3- <br /> UDC Depth: A9 ` <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: N 41,6111 , <br /> Portion of UDC Tested' 2"Above Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> Penetration Penetration Penetration Penetration <br /> Does turbine shut down when D Yes D No NAO D Yes D No NA® D Yes D No NA® D Yes D No NA® <br /> UDC sensor detects liquid. <br /> Turbine shutdown response time D Yes D No NA® D Yes D No NA® D Yes D No NAD D Yes D No NA® <br /> Is system programmed for fail- D Yes D No NA® D Yes D No NA® D Yes D No NA® D Yes D No NA® <br /> safe shutdown?* <br /> Was fail-safe verified to be D Yes D No NA® D Yes D No NA® D Yes D No NAM D Yes D No NA® <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: -2:60 <br /> y 3 .25 <br /> Initial Reading(RO: P2.2 y 71, 1_e f yz2..3j1.s1' <br /> Test End Time: ; <br />
The URL can be used to link to this page
Your browser does not support the video tag.