ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2008-2009
RECORD_ID
PR0231094
PE
2361
FACILITY_ID
FA0003632
FACILITY_NAME
AJS MINI MART INC
STREET_NUMBER
7906
Direction
N
STREET_NAME
EL DORADO
STREET_TYPE
ST
City
STOCKTON
Zip
95207
APN
07935016
CURRENT_STATUS
01
SITE_LOCATION
7906 N EL DORADO ST
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231094_7906 N EL DORADO_2008-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
421
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OCT -27-2008 02:58 PM GETTLER—RYAN INC. 925 551 4770 P.03 <br />0 <br />t nitoring system C'ertitiention <br />D. Results of Testing/Servicing <br />Software Version Installed: 327,04 <br />Cnnenhop tha rnllnwlnn nhonrrlr®e. <br />® Yes <br />❑ No* <br />Is the audible alarm operational? <br />® Yes <br />❑ No* <br />Is the visual alarm operational? <br />❑ Yes <br />Q No' <br />Were all sensors visually inspected, Functionally tested, and confirmed operational? <br />0 Yes <br />❑ No* <br />Were all sensors insta)led at lowest point of* secondary containment and positioned so that other equipment will <br />not interfere with their proper operation" <br />❑ Yes <br />❑ No* <br />_ <br />It alarms are relayed to a remote monitoring station. is all communications equipincrit (e.g.. modem) <br />Z N/A <br />operational"? <br />® Yes <br />❑ No* <br />For pressurized piping systems, clues the turbine automatically shut down if the piping sccondary containment <br />❑ N/A <br />monitoring system detects a leak. flails to operate, or is electrically disconnected? if yes. which sensors initiate <br />positive shut -down? (Cheek all that a,pp4v) Z Sump.' french Sensors; ❑ Dispenser Contaimnent Sens__ <br />Did you confirm positive shut -down due to leaks gjn sensor failure/discon.nection? 0 Yes, 0 No. <br />❑ Yes <br />❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (Le„ no <br />E N/A <br />mechanical overfill prevention valve is installed). is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating properly? I 1',,;o, at what percent of tank capacity does the alarm trigger? q.I <br />❑ Yes* <br />9 No <br />_ <br />Was any monitoring equipment replaced? If yes, identify specific sensor., probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below, <br />❑ Yes¢ <br />9 No <br />Was liquid found inside any .4 condary containment systems designed as (try systems? (Check all that apply,) <br />❑ Product; ❑ Water. If yes, describe causes in Section E. below. <br />2 Yes <br />❑ Not <br />Was monitoring system set-up reviewed to ensure proper setting.? Attach set up reports, if applicable <br />10 Yes I <br />❑ No* I <br />Is all monitoring equipment operational per manufacturer's ,pecification,,;'? <br />* In Section F below, describe how and when these deflelencies were or ®vill be corrected. <br />E. Comments: Only the 87 STP V/R 323 sensors were tested. Alarm history and system set up report were not <br />needed in paperwork at the request of San Joaquin County inspector Garret Backus that was present at site. <br />Page 2 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.