Laserfiche WebLink
S A N 3J Q A Q U I MENDEDEnvironmental Health Department <br /> _. C 0 U N TY---- 2U <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TIWANA GAS&FOOD 1 1210 E HAMMER LN, STOCKTON June 29,2018 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 208 CCR 2650(e), 2652 Failed to notify the EHD of a reportable unauthorized release. <br /> When the inspector and service technicians arrived on site approximately 30 gallons of fuel was observed in the 91 <br /> STP sump was not reported to the EHD within 24 hours and a full report has not been submitted to the EHD within <br /> five working days.The monitoring sensor(1-5)has been in active alarm since 3/29/2018.The service technician <br /> tested the functionality of the sensor and verified that it was working properly.The site owner was aware of the <br /> alarm but stated that they had not been using the tank since the L5 went into alarm, however it was unclear whether <br /> anyone had addressed the alarm since 3/29/2018. No maintenance records of this alarm being addressed were <br /> found on site. Any release from the primary containment that does not escape the secondary containment and was <br /> cleaned up within eight hours of being detected shall be recorded with the following information: <br /> 1. Operator's name and phone number <br /> 2. List of types,quantities, and concentrations of hazardous substances released <br /> 3. Description of actions taken to control and clean the release <br /> 4. Method and location of disposal of the released substances <br /> 5. Description of actions taken to repair and prevent future releases <br /> 6. Description of method used to reactivate interstitial monitoring after repair or replacement of primary containment <br /> Immediately record this release with the information required, and maintain it on site with the facility's monitoring <br /> records. Submit a copy of the recordable release statement to the EHD. <br /> This is a Class II violation. <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br /> The designated operator failed to visually inspect the 91 STP sump for leaks,water, or debris during the 4/3/2018, <br /> 5/2/2018, and 6/1/2018 monthly inspection. During the monthly inspection,the designated operator shall visually <br /> inspect all spill containers and UDC sumps,and any tank top sump that had an alarm for which there is no record of <br /> a service visit. Ensure that designated operators performing monthly inspections at this facility are inspecting all of <br /> the required areas and noting it on the on the reports. <br /> The designated operator failed to check and note the correct test dates for the secondary containment testing on <br /> the June 2017-June 2018 designated operator monthly inspection report.The designated Operator stated that the <br /> test was conducted on 10/3/2017 and 7/8/14 however EHD records show the routine secondary containment testing <br /> to have occurred on 7/31/17. During the monthly inspection,the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and document the dates they were done. <br /> Ensure that designated operators performing monthly inspections at this facility are including all of the required <br /> information on the reports. <br /> This is a Class 11 violation. <br /> FA0003730 PR0231125 SCO01 06/29/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 6 of 8 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />