My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2003
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1469
>
2300 - Underground Storage Tank Program
>
PR0231126
>
COMPLIANCE INFO_1999-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:00 AM
Creation date
6/23/2020 6:44:16 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2003
RECORD_ID
PR0231126
PE
2361
FACILITY_ID
FA0001570
FACILITY_NAME
UNITED # 5447
STREET_NUMBER
1469
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95210
APN
08818030
CURRENT_STATUS
01
SITE_LOCATION
1469 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231126_1469 E HAMMER_1999-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
267
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> ' <br /> Software Version Installed: / J r ) <br /> Complete the follo ng checklist: <br /> re ❑ No* Is the audible alarm o rational? <br /> ❑ No* Is the visual alarm o tional? <br /> ❑ No* Were all sensors visual) ins ted,functional) tested,and confirmed o rational? <br /> ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their ro er o ration?❑ Dlo* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> �N/A operational? <br /> ❑ No* For prressurized_piping stems, does the turbin 'automatically shut down if the piping secondary containment <br /> ❑ N/A monitoring system detects a leak,fails to ope e,or is electrically disconnected? If y : which sensors initiate <br /> positive shut-down? (Check all that apply) Sump/Trench Sensors; ❑Dispensertainment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? Yes; ❑No. <br /> C3-Yes ❑ o* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> N A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> 7 <br /> fill int(s)and operating ro rl ? If so,at what 2Ecent of tank capacity does the alarm trigger? % <br /> ❑ Yes* CVNo Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and Iist the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply)13Product; E3Water. If es,describe causes in Section E,below. <br /> es ❑ No* I Was monitorin system set-u2 reviewed to ensure 2Tper settings?Attach set up re22rts,if a2plicable <br /> Yes ❑ No* Is all monitorin ui ment operational, r manufacturer's specifications? <br /> *In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> Page 2 of 3 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.