Laserfiche WebLink
SAN O�^�I N Environmental Health Department <br /> COUNTY <br /> SM <br /> U �delrgra[� Morabox <br /> 'Tank Paigram spec#ta Repo .:s <br /> Facility Name: Facility Address: Date: <br /> UNITED#5447 1469 E HAMMER LN, STOCKTON August 02,2018 <br /> UN OF VLATIONS <br /> MCO <br /> . - <br /> :, (CLASS I,CL/1SS 11,or MINQR M1�Iotice to Complrj <br /> Item# Remarks <br /> 319 CCR 2635(b)No spill bucket,failed to contain five gallons, or failed to provide a means to keep it empty. <br /> The 91 direct-bury spill container failed when tested. All spill containers shall have a minimum capacity of five <br /> gallons and be capable of containing a spill or overfill until it is detected or cleaned up. Immediately discontinue <br /> deposition of petroleum into this tank until the component is repaired or replaced by a properly licensed,trained, and <br /> certified contractor under permit and inspection of the EHD. If the spill container can't be replaced immediately, <br /> there is a possibility that the 91 UST system may be red tagged to prevent fuel inputs. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork within 30 days of receipt of this report. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer(if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Note: The 89-product Veeder root 208 STP sensor failed to provide shutdown to the turbine when tested to <br /> ensure continuous monitoring of the tank system. According to the technician, the 89-turbine relay needs to be <br /> replaced. Since positive shutdown is not functional on the 89 UST system, in lieu of positive shutdown, a line <br /> test can be performed. The onsite technician, Richard Thomas, performed a line test. Certifications: Tank tester <br /> -#06-1672, exp: 6/30/21; Triangle-exp: 12/01/19. Line test passed. <br /> AFTER THE COMPLIANCE DATE,EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: August 02,2018 Inspector: Inspector Phone: <br /> n Printed Name and Title: AARON HANG, REHS (209)468-3453 <br /> J ` Janene Asuncion, Manager <br /> FA0001570 PR0231126 SC001 08/02/2018 <br /> EHD 23-01 Rev.10/31/2017 Page 5 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />