My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1612
>
2300 - Underground Storage Tank Program
>
PR0231127
>
COMPLIANCE INFO_2002-2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2021 1:48:44 PM
Creation date
6/23/2020 6:44:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2009
RECORD_ID
PR0231127
PE
2361
FACILITY_ID
FA0003611
FACILITY_NAME
PARKWOODS GAS & FOOD
STREET_NUMBER
1612
Direction
W
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95209
APN
07728002
CURRENT_STATUS
01
SITE_LOCATION
1612 W HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231127_1612 W HAMMER_2002-2009.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
449
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Alonk -ring System Certification <br />II 1 <br />Lori= <br />VS.= On= <br />Is the audible alarm operational? <br />rM Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their proper operation? <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g., modem) <br />operational? <br />For pressurized piping systems, does the turbuie automatically shut down if the piping secondary containment <br />monitoring system detects a leak, fails to operate, or is electricaW disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) 0 Sump/Trench Sensors; 0 Dispenser Containment Sensors. <br />Did you confirin positive shut -down due to leaks and sensor failure/disconnection? 0 Yes; 0 No. <br />rmv=, For tank systems that utilize the monitoring system as the primary tank overfill warning device Fie-, no7 <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank:: <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? 90% <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br />replaced and list the manufacturer name and model for all replacement parts in Section E, below. <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />0 Product; 0 Water. If yes, describe causes in Section E, below. <br />�-Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />��: <br />-Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when the deficiencies were or will be corrected. <br />E. Comments: <br />
The URL can be used to link to this page
Your browser does not support the video tag.