Laserfiche WebLink
i <br />F <br />0 0 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sagov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility Parkwoods Gas & Food <br />VIOLATIONS <br />AddrIesss: 1612 W Hammer Lane, Stockton <br />oats°n May 1, 2013 <br />Name: <br />M <br />Code Section <br />HSC = California Health and SafetyCode; CCR = California Code of Regulations <br />Facility <br />Jesse Tiwana <br />File Review <br />Title: <br />I Manager <br />Phone: <br />951-9708 <br />Contact <br />Annual operating fees not paid <br />103 HSC 25284(a)(3) <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 <br />Inspection X Routine X Monitoring System Certification ❑ Installation ❑ Complaint - ID#: ❑ Other <br />Type: <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 CCR 2632(b) <br />(Authority HSC 25289) <br />107 CCR 2632(d)(1)(C) <br />er Mana <br />Tiwana Title: g <br />Consentfor. XInspection XSampling XPhotos <br />Grantedby:Jesse <br />Monitoring Veeder-Root TLS -350 <br />Piping <br />Pressurized I.1 Suction ❑Gravity <br />Overfill <br />Prevention: Mechanical ❑Audible/visual <br />Panel: <br />System: <br />112 CCR 2636(f)(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />UST <br />67 <br />114 CCR 2715(b) <br />8 <br />115 CCR 2660(k) <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 <br />------ <br />------- <br />--------------Product <br />- ---octane <br />rl�octane- <br />--DSL-- <br />Permit to close UST system not obtained <br />-------------- <br />On Site Records <br />-------------- <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/2 years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 X CCR 2712(1) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />Designated <br />Karen Arnaiz <br />6-11-2013 <br />Violations: XM1-Release Detection F] M2 -Release Prevention [ M3 -Both <br />Operator <br />Date:: <br />Dat <br />On Site Service <br />DaVld Winkler <br />ICC Exp. Manufacturer's <br />3-3-14 Training: TT -3-31-14; VR -2-13-14; -11-10-13 <br />Technician: <br />Date: <br />VMI <br />Inspedor Reca Title: <br />Garrett Backus (209) 468-2986 <br />D 1 UST INSPECTION REPO <br />EHD 23-02 Rev 04/19/12 age <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = California Health and SafetyCode; CCR = California Code of Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />File Review <br />101 HSC 25284 <br />No permit to operate <br />102 HSC 25404.5 <br />Annual operating fees not paid <br />103 HSC 25284(a)(3) <br />No written agreement between the person that the operating permit was issued to and the tank operator to <br />monitor the tanks stem <br />104 HSC 25292.2 <br />Current financial responsibility documents not on file with the Environmental Health Department (EHD) <br />105 CCR 2711 <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />106 CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />107 CCR 2632(d)(1)(C) <br />Plot plan/site map not submitted or fails to completely show where monitoring is performed <br />108 CCR 2637 <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (f) test notification <br />not provided to the EHD at least 48 hours prior to conducting the test <br />109 CCR 2638 <br />Monitoring equipment certification: (a) not performed annually; (d) test report not submitted within 30 days; <br />(e) test notification not provided to the EHD at least 48 hours prior to conducting an installation, repair, <br />replacement, calibration, or certification <br />110 HSC 25291(f) <br />Annual line leak detector test not performed (M1) <br />111 HSC 25284.2 <br />Annual spill containment testing not performed <br />112 CCR 2636(f)(4) <br />Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br />113 CCR 2715(a) <br />Failed to inform the EHD of a change of designated operator within 30 days <br />114 CCR 2715(b) <br />Designated operator does not possess a current ICC CA UST System Operator certification <br />115 CCR 2660(k) <br />Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br />permit conditions <br />116 HSC 25292.5 <br />Enhanced leak detection (ELD) testing not performed on a system located within 1000' of public well, or <br />failures not repaired and retested <br />117 CCR 2661 <br />Permit to repair UST system not obtained <br />118 HSC 25286(a) <br />Operational permit not amended when UST storage and/or monitoring system changed <br />119 HSC 25298(b) <br />Permit to temporarily close UST system not obtained <br />120 HSC 25298(c) <br />Permit to close UST system not obtained <br />On Site Records <br />201 CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/2 years, written <br />performance claims pertaining to release detection systems for 5 years, or records of repairs, linings, and <br />upgrades for the life of the tank. Monitoring records include: (1) date and time of all monitoring or sampling; <br />(2) monitoring equipment calibration and maintenance records; (3) results of any visual observations; (4) <br />results of sample analysis performed a lab or in the field; (5) logs of all readings of gauges or other monitoring <br />equipment, round water elevations, or other test results; 6 results of inventory readings and reconciliations <br />202 X CCR 2712(1) <br />Monitoring plan, response plan, and/or operating permit and all conditions not onsite <br />203 CCR 2650 <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight hours (M1) <br />was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a sudden loss of <br />°r°duct was not reported to the EHD within 24 hours <br />Inspedor Reca Title: <br />Garrett Backus (209) 468-2986 <br />D 1 UST INSPECTION REPO <br />EHD 23-02 Rev 04/19/12 age <br />