COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HUNTER
>
642
>
2300 - Underground Storage Tank Program
>
PR0231148
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/2/2021 2:35:10 PM
Creation date
6/23/2020 6:45:03 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231148
PE
2361
FACILITY_ID
FA0000799
FACILITY_NAME
STOCKTON MOBIL #1
STREET_NUMBER
642
Direction
N
STREET_NAME
HUNTER
STREET_TYPE
ST
City
STOCKTON
Zip
95202
APN
13906035
CURRENT_STATUS
01
SITE_LOCATION
642 N HUNTER ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231148_642 N HUNTER_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
WK <br />UNIFIED PROGRAM CONSOLIDATED FORM <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN (Page 2 of 2) <br />VI. UNDER DISPENSER CONT T (UDC) MONITORING <br />1. UDC MONITORING IS PERFORMED USING THE FOLLOWING METHOD 490-54a <br />490-54b <br />0.3. <br />,1. CONTINUOUS ELECTRONIC MONITORING ❑ 2. FLOAT AND CHAIN ASSEMBLY ELECTRONIC STAND-ALONE <br />❑ 4. NO DISPENSERS ❑ 99. OTHER (Specify): <br />PANEL MANUFACTURER: v 490-55 <br />MODEL #: L S - 490-56. <br />LEAK SENSOR MANUFACTURER 490-57 <br />MODEL #(S): - W 1LI ®' 490-58 <br />DETECTION OF A LEAK INTO THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS a a. YES ❑ b. NO 490-59 <br />UDC LEAK ALARM TRIGGERS AUTOMATIC PUMP SHUTDOWN ❑ a. YES (5b. NO 490.60. <br />FAILURE / DISCONNECTION OF UDC MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a. YES §1 b. NO 49Mm <br />UDC MONITORING STOPS THE FLOW OF PRODUCT AT THE DISPENSER 0 a. YES ❑ b. NO 490-62 <br />2. UDC CONSTRUCTION IS CK SINGLE -WALLED ❑ 2. DOUBLE -WALLED 490-63 <br />IF DOUBLE WALLED: 49064a <br />UDC INTERSTITIAL SPACE IS MONITORED BY: 1. LIQUID 2. PRESSURE Q 3. VACUUM <br />A LEAK WITHIN THE SECONDARY CONTAINMENT OF THE UDC TRIGGERS AUDIBLE AND VISUAL ALARMS ❑ a. YES ❑ b. NO 490.64b <br />VII. PERIODIC SYSTEM TESTING <br />1. ELD TESTING: THIS FACILITY HAS BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT ENHANCED 49x65• <br />LILAIS DEjLUjQN_LE_L_Dj MUST BE PERFORMED. PERIODIC ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED. 23 CCR 2644.1 <br />%2. SECONDARY CONTAINMENT COMPONENTS ARE TESTED EVERY 36 MONTHS. 490.66 <br />SPILL BUCKETS ARE TESTED ANNUALLY. 490.67 <br />VIII. RECORDKEEPING <br />The following monitoring/maintenance records are kept for this facility: <br />,Alarm logs 490-68a Visual Inspection Records 490.68b ❑ Tank integrity testing results 49"k <br />❑ SIR testing results (and supporting documentation records). 490-68d ❑ Tank gauging results (and supporting documentation records). 490-68e <br />❑ ATG Testing results (and supporting documentation records). 490<8f ❑ Corrosion Protection 60 -day logs 49o.68g <br />❑ Equipment maintenance and calibration records. 490-6sh <br />DL TRAINING <br />ersonnel with UST monitoring responsibilities are familiar with all of the following documents relevant to their job duties. 490.69a <br />REFERENCE DOCUMENTS MAINTAINED AT FACILITY (Check all that apply) <br />THIS UNDERGROUND STORAGE TANK MONITORING PLAN (Required) 49o -69b <br />OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT (Required) 440.69e <br />❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS 490-69d <br />CALIFORNIA UNDERGROUND STORAGE TANK LAW 490-69a <br />STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br />STATISTICAL INVENTORY RECONCILIATION" 490.69f <br />❑ SWRCB PUBLICATION: "UNDERSTANDING AUTOMATIC TANK GAUGING SYSTEMS" 490.698 <br />❑ OTHER (Specify): M69h, M69i <br />Ed This facility has a "Designated UST Operator" who has passed the California UST System Operator Exam administered by the International Code Council (ICC). <br />The "Designated UST Operator" will train facility employees in the proper operation and maintenance of the UST systems annually, and within 30 days of hire. This <br />training will include, but is not limited to, the following: <br />• Operation of the UST systems in a manner consistent with the facility's best management practices <br />• The facility employee's role with regard to the monitoring equipment as specified in this UST Monitoring Plan <br />• The facility employee's role with regard to spills and overfills as specified in the UST Response Plan <br />• Names of contact person(s) for emergencies and monitoring alarms. 490-70 <br />X. CO S/ADDITIONAL INFORMATION . P. , <br />Provide additional comments here or indicate how many pages with �additional information on specific monitoring procedures are attached top plan. 49o -7i <br />M. PERSONNEL RESPONSIBILITIES <br />The UST Owner/Operator is responsible for ensuring that: 1) the daily/routine UST monitoring activities and maintenance of UST leak detection equipment covered by <br />this plan occurs, 2) all conditions that indicate a possible release are investigated, and 3) all monitoring records are maintained properly. <br />The following person(s) are responsible for performing the monitoring and equipment maintenance: <br />NAME 49o-72 TITLE 490-73 <br />NAME 490-74 TITLE 490.75 <br />The Designated Operator shall perform a monthly visual inspection of the facility, provide a report to the owner/operator, and inform the owner/operator of any <br />conditions that need follow-up action. <br />XII. OWNER/OPERATOR SIGNATURE <br />CERTIFICATION: I certify that the information provided herein is true and accurate to the best of my knowledge. <br />APPLICANT 490-76 <br />DATE: 490-77 <br />REPRESD2 F 3. A RMmentativeofQBW <br />APPLICANT TITLE: 490-79 <br />APPLICANT ME (print): V 490.78 <br />lA t <br />UPCF UST -D (12/2007) 3/4 <br />r' �' Y <br />
The URL can be used to link to this page
Your browser does not support the video tag.