Laserfiche WebLink
San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.org/ehd <br />l�nderground $torage`Tarik Program Ins ect�on Re ort <br />P P <br />�. <br />Facility Name: <br />Facility Address: <br />Date: <br />SHOP N GO 3 <br />4511 PACIFIC AVE, STOCKTON <br />February 22, 2018 <br />SUMMARY OF VIOLATIONS <br />(CLASS, CLASS ll,aflr MINQR .Notice to Comply) <br />Item # <br />Remarks <br />104 <br />CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />UST Facility Operating Permit is not current in CERS. The Board of Equalization (BOE) number, 44040786, is <br />closed and not valid. Contact the Board of Equalization at 1-800-400-7115 to get a valid number. Any change of <br />information must be updated in CERS within 30 days of the changes. Immediately log into CERS, update the <br />required information, and submit for review by the EHD. <br />This is a repeat violation, Class Il. <br />105 <br />CCR 2632(d)(1), 2634(d) Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. Beneath "Tank Monitoring is Performed Using <br />the Following Method(s)", enter "Dry" for "Secondary Containment System" for both the 91 and 87 tanks. Beneath <br />"Under Dispenser Containment (UDC) Monitoring", for both the 91 and 87 tanks, "UDC Monitoring Stops Flow of <br />Product at Dispenser' is incorrectly marked "Yes," and should be marked as "No." The monitoring plan must be <br />uploaded to the California Environmental Reporting System (CERS). Immediately log into CERS, make the <br />necessary changes, and submit for review by the EHD. <br />This is a repeat violation, Class Il. <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. The L1 liquid sensor should be associated with the <br />87 -unleaded subersible turbine pump (STP) sump and the L3 sensor should be associated with the 87 -unleaded <br />annular space-, the L2 sensor should be associated with the 91 -supreme STP sump and the L4 sensor should be <br />associated with the 91 -supreme annular space. Also, the approximate location of the underground storage tank <br />piping is missing from the site plan. A site plan must be submitted identifying the locations where monitoring will be <br />performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />This is a repeat violation, Class II. <br />113 <br />CCR 2638(d) Failed to submit monitoring system certification test report within 30 days. <br />Annual monitoring system certification, leak detector testing, and spill container testing was performed on 2/27/2017 <br />and a test report was submitted on 4/24/2017 , over 3 weeks late. A copy of the test report must be submitted <br />within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports are <br />performed in a timely manner. <br />This is a repeat violation, Class II. <br />FA0002480 PR0231216 SCO01 02/22/2018 <br />EHD 23-01 Rev. 09/22/16 Page 4 of 6 Underground Storage Tank Program OIR <br />