My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4511
>
2300 - Underground Storage Tank Program
>
PR0231216
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:22:00 PM
Creation date
6/23/2020 6:45:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231216
PE
2361
FACILITY_ID
FA0002480
FACILITY_NAME
SHOP N GO 3
STREET_NUMBER
4511
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11023011
CURRENT_STATUS
01
SITE_LOCATION
4511 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231216_4511 PACIFIC_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
376
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br />• <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br />Underground Storage Tank Program In pection RepaIE <br />_* <br />Facility Name: <br />Facility Address: <br />Date: <br />SHOP N GO 3 <br />4511 PACIFIC AVE, STOCKTON <br />February 22, 2018 <br />SU11�111►RY OF VIOLATIONS <br />(CLASS !, CUSS 11, or MINOR - Nobce to Compty) ¥` <br />Item # <br />Remarks <br />121 <br />CCR 2712(f) Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on 2/27/2017 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by 3/29/2017 . This <br />information has not been received resulting in a non-compliant status for this facility. An operator that receives an <br />inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br />actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br />corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. <br />Open violations from the 2016 inspection: <br />- Failed to test spill containers annually <br />- Current financial responsibility documents not submitted <br />- Failed to test monitoring and leak detection equipment annually <br />- Failed to submit monitoring system certification test report within 30 days <br />- Failed to maintain alarm logs and/or records of follow up actions <br />- Designated operator did not inspect all required items and/or the inspection reports not completed <br />Open violations from 2017: <br />- Failure to construct, operate, and maintain primary containment as product -tight <br />- Current financial responsibility documents not submitted <br />- Plot plan/site map not submitted or failed to completely show where monitoring is performed <br />- Failed to have an approved UST monitoring plan <br />- Failed to submit monitoring system certification test report within 30 days <br />- UST operating permit application for facility and tank information not submitted or current <br />- Failed to submit a written response within 30 days of receiving an inspection report <br />This is a repeat violation, Class 11. <br />313 <br />HSC 25290.1, 25290.2, 25291 Failure to construct, operate, and maintain primary containment as product -tight. <br />Seepage was observed above the shear valves in under dispenser containment (UDC) 3/4, indicating a leak in the <br />primary piping. All primary containment for the UST system must be tight. Immediately have a properly licensed, <br />trained, and certified contractor repair or replace the failed component under permit and inspection of the EHD. <br />This is a repeat violation, Class 11. <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 3/24/2018 . <br />Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br />documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br />Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br />applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br />Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br />FA0002480 PR0231216 SCO01 02/22/2018 <br />EHD 23-01 Rev. 09/22/16 Page 5 of 6 Underground Storage Tank Program OR <br />
The URL can be used to link to this page
Your browser does not support the video tag.