My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4511
>
2300 - Underground Storage Tank Program
>
PR0231216
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:22:00 PM
Creation date
6/23/2020 6:45:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231216
PE
2361
FACILITY_ID
FA0002480
FACILITY_NAME
SHOP N GO 3
STREET_NUMBER
4511
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11023011
CURRENT_STATUS
01
SITE_LOCATION
4511 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231216_4511 PACIFIC_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
376
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br />The following is an itemized list of underground storage tank violations that have not <br />been addressed for SHOP N GO 3 as of August 21, 2017. <br />Open violations from February 27, 2017 inspection <br />Violation #103 - Current financial responsibility documents not submitted. <br />The Certification of Financial Responsibility documents submitted to the California Environmental Reporting System <br />(CERS) have not been signed by the owner or operator of the underground storage tanks. Current financial <br />responsibility documents are required to be submitted annually. Immediately log into CERS at <br />http://cers.calepa.ca.gov/, and upload the required documents. <br />Violation #104 - UST operating permit application for facility and tank information not submitted or current. <br />UST Facility Operating Permit is not current in CERS. The Board of Equalization number, 44040786, is closed and <br />not valid. Contact the Board of Equalization and get a valid number. Any change of information must be updated in <br />CERS within 30 days of the changes. Immediately log into CERS, update the required information, and submit for <br />review by the EHD. <br />Violation #105 - Failed to have an approved UST monitoring plan. <br />The monitoring plan is not current and/or not approved by the EHD. Beneath Tank Monitoring is Performed Using <br />the Following Method(s), enter" Dry" for Secondary Containment System for both underground storage tanks. The <br />monitoring plan must be uploaded to the California Environmental Reporting System (CERS). Immediately log into <br />CERS, make the necessary changes, and submit for review by the EHD. <br />Violation #107 - Plot plan/site map not submitted or failed to completely show where monitoring is <br />performed. <br />An accurate UST Monitoring Site Plan was not submitted. The L1 liquid sensor should be associated wtih the <br />87 -unleaded submersible turbine pump (STP) sump and the L3 sensor should be associated with the 87 -unleaded <br />annular space; the L2 sensor should be associated with the supreme STP sump and the L4 sensor should be <br />associated with the supreme annular space. A site plan must be submitted identifying the locations where <br />monitoring will be performed. Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site Plan. <br />Violation #113 - Failed to submit monitoring system certification test report within 30 days. <br />Annual monitoring system certification, leak detector testing, and spill container testing was performed on 5/10/16 <br />and a test report was submitted on 2/1/2017 , more than seven months late. A copy of the test report must be <br />submitted within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports <br />are performed in a timely manner. <br />Violation #121 - Failed to submit a written response within 30 days of receiving an inspection report. <br />An inspection was last done on May 10, 2016 and an inspection report was issued identifying information to be <br />submitted to bring this site into compliance. This information was required to be submitted by June 10, 2016. This <br />information has not been received resulting in a non-compliant status for this facility. An operator that receives an <br />inspection report shall have 30 days to submit a written response that includes a statement documenting corrective <br />actions taken or proposing corrective actions which will be taken. Ensure that a written response documenting <br />corrective actions taken or proposed is submitted within 30 days of receiving an inspection report. Outstanding <br />violations from the 2016 inspection include: Current financial responsibility documents not submitted; failed to test <br />monitoring and leak detection equipment annually; failed to test spill containers annually, failed to submit monitoring <br />system certification test report within 30 days; failed to maintain alarm logs and/or records of follow up actions; and <br />designated operator did not inspect all required items and/or the inspection reports not completed. Immediately <br />respond and address the listed violations from the 2016 inspection report. <br />Violation #313 - Failure to construct, operate, and maintain primary containment as product -tight. <br />Seepage was observed above the shear valves in under dispenser containment (UDC) 3-4 indicating a leak in the <br />primary piping. All primary containment for the UST system must be tight. Continue to monitor for seepage and if <br />the seepage persists, immediately have a properly licensed, trained, and certified contractor repair or replace the <br />failed components. <br />Open violations from May 10, 2016 inspection <br />Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.