My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4511
>
2300 - Underground Storage Tank Program
>
PR0231216
>
COMPLIANCE INFO_2009-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:22:00 PM
Creation date
6/23/2020 6:45:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2018
RECORD_ID
PR0231216
PE
2361
FACILITY_ID
FA0002480
FACILITY_NAME
SHOP N GO 3
STREET_NUMBER
4511
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11023011
CURRENT_STATUS
01
SITE_LOCATION
4511 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231216_4511 PACIFIC_2009-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
376
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />The following is an itemized list of underground storage tank violations that have not <br />been addressed for SHOP N GO 3 as of August 21, 2017. <br />Open violations from May 10, 2016 inspection <br />Violation #103 - Current financial responsibility documents not submitted. <br />Financial responsibility documents have not been submitted to the EHD. Current financial responsibility documents <br />are required to be submitted annually. Immediately log into the California Environmental Reporting System (CERS) <br />at http://cers.calepa.ca.gov/, and upload the required documents. <br />Violation #111- Failed to test monitoring and leak detection equipment annually. <br />Annual monitoring system certification and leak detector testing were last performed on February 10, 2015 and was <br />completed on May 10, 2016 , three months past due. These tests are required once every 12 months. Take all <br />necessary precautions to ensure testing is performed in a timely manner. <br />Violation #112 - Failed to test spill containers annually. <br />Annual spill container testing was last performed on February 10, 2015 and was completed on May 10, 2016 , three <br />months past due. This test is required once every 12 months. Take all necessary precautions to ensure testing is <br />performed in a timely manner. <br />Violation #113 - Failed to submit monitoring system certification test report within 30 days. <br />Annual monitoring system certification, leak detector testing, and spill container testing was performed on February <br />10, 2015 and a test report was submitted on March 27, 2015 , 1/2 month late. A copy of the test report must be <br />submitted within 30 days of the tests. Take all necessary precautions to ensure testing and submittal of test reports <br />are performed in a timely manner. <br />Violation #201 - Failed to maintain alarm logs and/or records of follow up actions. <br />Maintenance and monitoring records for the last three years were not found on site. The 2013 and 2015 monitoring <br />system certification test results. These records shall be maintained on site for at least three years. Monitoring <br />records include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and <br />maintenance records; (3) results of any visual observations; (4) results of sample analysis performed a lab or in the <br />field; (5) logs of all readings of gauges or other monitoring equipment, ground water elevations, or other test results; <br />(6) results of inventory readings and reconciliations. Immediately locate and maintain all maintenance and <br />monitoring records for the last three years on site and submit copies to the EHD. <br />Violation #209 - Designated operator did not inspect all required items and/or the inspection reports not <br />completed. <br />The designated operator failed to check and note the correct test dates for the monitoring system certification test <br />and the spill containment testing on the February 2015 through April 2016 designated operator monthly inspection <br />report. The incorrect date listed 2-17-15. The correct date on file is 2-10-15. During the monthly inspection, the <br />designated operator shall check that all required testing and maintenance for the UST system have been completed <br />and document the dates they were done. Ensure that designated operators performing monthly inspections at this <br />facility are including all of the required information on the reports. <br />Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.