COMPLIANCE INFO_2009-2012 DOUBLE CHECK
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
9321
>
2300 - Underground Storage Tank Program
>
PR0231261
>
COMPLIANCE INFO_2009-2012 DOUBLE CHECK
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:56:44 PM
Creation date
6/23/2020 6:45:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012 DOUBLE CHECK
RECORD_ID
PR0231261
PE
2361
FACILITY_ID
FA0002890
FACILITY_NAME
QUIK STOP MARKET #2120*
STREET_NUMBER
9321
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
080-180-05
CURRENT_STATUS
01
SITE_LOCATION
9321 N THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231261_9321 N THORNTON_2009-2012 DOUBLE CHECK.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
287
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TANK ANNULAR TESTING <br /> Test Method By: • Manufacturer O Industry Standard O Professional Engr. O Other(see below) <br /> Test Method Uses: O Pressure • Vacuum o Hydrostatic o Other(see below) <br /> Measuring Equipment Used: Vacuum Gauge (range 0 to 30 inches Hg) <br /> Description Tank#1 Tank#2 <br /> Product stored Gasoline-91 Gasoline-87 <br /> Tank manufacturer Xerxes Xerxes <br /> Tank material FRP FRP <br /> Tank capacity (US gallons) 12,000 12,000 <br /> Is this a multi-compartment tank? No No <br /> Dry or Brine filled annular? Brine Brine <br /> Monitoring system show normal annular? Yes Yes <br /> Is water table above tank bottom? Unknown Unknown <br /> Was sensor removed for testing? N/A _ N/A <br /> Was sensor properly replaced after testing? N/A N/A <br /> Wait time for vacuum to stabilize (hr:min) <br /> Test start time — <br /> Initial vacuum (inches Hg) <br /> Test end time - <br /> Final vacuum (inches Hg) <br /> Test duration (hr.min) <br /> Change in vacuum (inches Hg) <br /> Pass/Fail threshold (inches Hg/hour) <br /> TEST RESULT <br /> Comments: <br /> These tanks have brine filled annulars. Vacuum testing is not required. <br /> © 2012 Walton Engineering,Inc. <br />