My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
A
>
ACKERMAN
>
1725
>
2300 - Underground Storage Tank Program
>
PR0231309
>
COMPLIANCE INFO_2002-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2022 3:24:31 PM
Creation date
6/23/2020 6:45:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2012
RECORD_ID
PR0231309
PE
2361
FACILITY_ID
FA0003756
FACILITY_NAME
KISHIDA, GEORGE INC
STREET_NUMBER
1725
STREET_NAME
ACKERMAN
STREET_TYPE
DR
City
LODI
Zip
95240
APN
06219001
CURRENT_STATUS
01
SITE_LOCATION
1725 ACKERMAN DR
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231309_1725 ACKERMAN_2002-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• SAN JOAQUIN COUNTY 40 <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sicioy.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Name: George Kishida Trucking Inc. <br />Address: 1725 Ackerman Dr. Lodi CA 95240 <br />Inspection <br />ate tion Nov 15, 2011 <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS 11, or MINOR -Notice to Comply) <br />On site to witness the annual monitoring system certification testing and conduct a routine inspection. <br />Class II Violations: 109, 204, 206, 302, and 304. <br />109. Annual monitoring system certification, leak detector testing, line integrity test, and spill container <br />testing was performed on 11-10-10 and a test report was submitted to the EHD on 11-15-11. A copy of <br />the test report must be submitted within 30 days of the tests. Ensure that a copy of the test reports are <br />submitted to the EHD within 30 days of the tests. <br />204. The designated operator failed to check and note the test date for the line test on the 11-10-10 and <br />12-15-10 designated operator monthly inspection reports. The designated operator listed the monitoring <br />certification, spill container, and leak detector testing as 11-12-10 on the 12-15-10 designated operator <br />monthly inspection report. It should have been listed as 11-10-10. During the monthly inspection, the <br />designated operator shall check that all required testing and maintenance for the UST system have been <br />completed and document the dates they were done. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. <br />204. The designated operator failed to attach the alarm history report to the 1-24-11, 3-9-11, and <br />10-6-11 designated operator monthly inspection reports. During the monthly inspection, the designated <br />operator shall review the alarm history for the previous month, check that each alarm was documented <br />and responded to appropriately, and attach a copy of the alarm history with documentation taken in <br />response to any alarms to the monthly report. Ensure that designated operators performing monthly <br />inspections at this facility are including all of the required information on the reports. <br />206. Before today's training, the designated operator employee training for Marcos Ortega III <br />last occurred on 11-25-09 and for Kelli Kishida on 7-15-10. Marcos Ortega's training is considered <br />two years late. Kelli Kishida's training is considered four months late. The designated operator shall <br />train facility employees for which he or she is responsible in the proper operation and maintenance <br />of the UST system once every 12 months. The training shall include, but is not limited to: <br />1. Operation of the UST system in a manner consistent with the facility's best management practices. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Inspector: Received By:IZ <br />Title: <br />_I-11323-02 Rev 09!01/11 Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.