My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2010-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/25/2022 2:52:45 PM
Creation date
6/23/2020 6:46:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2011
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2010-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 0 <br /> 286 to 560 48 0.093 <br /> MI5.1 INSPECTOR QUALIFICATION 561 to 1100 64 0.123 <br /> 1101 to 4000 84 0.167 <br /> A qualified person shall perform ultrasonic 4001 to 12000 126 0.240 <br /> inspection. 12001 to 20000 144 0.302 <br /> 20001 to 50000 144 0.365 <br /> MI5.2 GAUGING EQUIPMENT <br /> CAPABILITIES Note: The above tank metal thickness is the <br /> metal thickness requirements specified in UL - <br /> MI5.2.1 The thickness gauging equipment shall 58,table 3.1 and section 3.6. <br /> be capable of determining the thickness of the <br /> tank metal through the lining material. MI5.4.1.2 The original tank metal thickness <br /> shall be obtained from the tank manufacturer. <br /> MI5.2.2 The thickness gauging equipment shall <br /> have an accuracy of +/- 0.05mm. and a MI6.0 ULTRASONIC THICKNESS <br /> resolution of+/-0.05mm. GAUGING PROCEDURE <br /> MI5.2.3 Ultrasonic testing equipment shall be MI6.1 The interior tank surface shall be <br /> maintained in accordance with manufacturer's divided into sections and gauged as follows: <br /> instructions. <br /> MI6.1.1 WALLS -The tank cylinder wall shall <br /> MI5.3 SURFACE PREPARATION be divided into three-foot by three-foot sections <br /> beginning at one of the tank's ends at the <br /> MI5.3.1 After the tank has been emptied, the bottom and extending vertically around the <br /> tank circumference and horizontally along the <br /> interior tank surfaces shall be cleaned as tank's cylindrical length. Any additional area of <br /> required for the use of the ultrasonic thickness the tank's cylindrical sections which are less <br /> gauging equipment. than three feet by three feet shall be designated <br /> as additional sections (See Figure Bl of <br /> MI5.4 ORIGINAL TANK METAL Chapter B). <br /> THICKNESS <br /> MI5.4.1 Original tank metal thickness shall be <br /> established in accordance with either MI5.4. 1.1 <br /> or MI5.4.1.2 below. MI6.1.2 HEADS - Tank end caps heads shall <br /> be divided into four equal quadrants by <br /> extending horizontally and vertically from the <br /> MI5.4.1.1 Original tank metal thickness shall center of the end cap. Each quadrant shall be <br /> be based on the original tank metal thickness as divided into three-foot by three-foot sections <br /> listed below by the tank capacity and diameter. beginning at the center of the tank head and <br /> Capacily Diam.Original extending vertically and horizontally toward the <br /> tank walls. Any additional areas of the tank <br /> Thickness heads which are less than 3 foot by 3 foot shall <br /> U.S. gallons Inches Inches be designated as additional sections (see figure <br /> Up to 285 42 0.067 B2,Part 2 of Chapter B). <br />
The URL can be used to link to this page
Your browser does not support the video tag.