My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BECKMAN
>
351
>
2300 - Underground Storage Tank Program
>
PR0231310
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/30/2022 4:33:55 PM
Creation date
6/23/2020 6:46:14 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231310
PE
2361
FACILITY_ID
FA0003773
FACILITY_NAME
VAN DE POL ENT INC/PACIFIC PRIDE
STREET_NUMBER
351
Direction
N
STREET_NAME
BECKMAN
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04903015
CURRENT_STATUS
01
SITE_LOCATION
351 N BECKMAN RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231310_351 N BECKMAN_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
478
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L' <br />SWRCB, January 2002 Page of <br />16 I TT.T. UMVP C nNTATNMF.NT gTTMP TFgTiNG <br />Facility is Not Equipped With Fill Riser Containment Sums ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator Equipment Resolution: .002 <br />Fill Sump # 1 -Dyed Fill Sump # 2-91 Fill Sump # 3-87 Fill Sump # 4 - <br />Diesel -T-4 <br />pSumDiameter: <br />42" <br />42" 42" <br />42" <br />Sump Depth: <br />44" <br />45" 40" <br />47" <br />Height from Tank Top to Top of <br />Highest Piping Penetration: <br />No Piping <br />Penetrations <br />No Piping No Piping <br />Penetrations Penetrations <br />No Piping <br />Penetrations <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />16" <br />15" 14" <br />16" <br />Condition of sump prior to <br />testing: <br />Dry <br />Dry Dry <br />Dry <br />Portion of Sump Tested <br />Water Line 20" <br />Water Line 19" Water Line 18" <br />Water Line 20" <br />Sump Material: <br />Fiberglass <br />Fiberglass Fiberglass <br />Fiberglass <br />Wait time between applying <br />water and starting test: <br />5 Minutes <br />5 Minutes 5 Minutes <br />5 Minutes <br />Test Start Time: <br />8:52 <br />8:57 9:42 <br />9:47 <br />Initial Reading (RI): <br />001 <br />.001 .001 <br />.001 <br />Test End Time. <br />9:22 <br />9:27 10:12 <br />10:17 <br />Final Reading RF): <br />.001 <br />.001 .001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes 30 Minutes <br />30 Minutes <br />Chane in Reading RF-Ri): <br />0 <br />0 0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes .005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />Pass <br />"Pass Pass <br />Pass <br />Is there a sensor in the sump? <br />Yes <br />Yes Yes <br />Yes <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />Yes <br />Yes Yes <br />Yes <br />Was sensor removed for testing? <br />Yes <br />Yes Yes <br />Yes <br />Was sensor properly replaced and <br />verified functional after testing? <br />Yes <br />Yes Yes <br />Yes <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.