Laserfiche WebLink
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sj„aov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Name• Tesoro Shell #68151 Address: 35 N Cherokee Ln Lodi CA 95240 Date - <br />Jan 28, 2014 <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />On site to witness the monitoring system certification testing and perform the routine inspection. <br />201. The L4 diesel annular and L5 87 annular sensors alarmed on February 25, 2013. The designated <br />operator did not document these alarms on the monthly designated operator report nor were they <br />documented on the facility alarm log. These records shall be kept on site for at least 3 years. <br />Immediately locate and maintain the facility alarm log and submit copies to the EHD by February 28, <br />2014. <br />204. The designated operator failed to document all the alarms from the attached alarm history on the <br />March 11, 2013, designated operator monthly inspection report and failed to check that they were <br />responded to appropriately. The missing alarms include: the L4 diesel annular and L5 87 annular <br />sensors which alarmed on February 25, 2013. During the monthly inspection, the designated operator <br />shall review the alarm history for the previous month, check that each alarm was documented and <br />responded to appropriately, and attach a copy of the alarm history with documentation taken in response <br />to any alarms to the monthly report. Ensure that designated operators performing monthly inspections <br />at this facility are including all of the required information on the reports. <br />204. The designated operator failed to check and note the correct test dates for the monitoring system <br />certification, leak detector, and spill container tests on the November 5, 2013 designated operator <br />monthly inspection report. The test date was listed as 1-1-13, but should have been listed as 1-28-13. <br />The designated operator failed to check and note the correct test dates for the monitoring system <br />certification and spill container tests on the June 2013 through October 2013 designated operator <br />monthly inspection reports. The test date was listed as 1-23-13, but should have been listed as 1-28-13. <br />During the monthly inspection, the designated operator shall check that all required testing and <br />maintenance for the UST system have been completed and document the dates they were done. Ensure <br />that designated operator performing monthly inspections at this facility are including all of the required <br />information on the reports. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTIO1 AT ANY TIME AT EH CURRENT HOURLY RATE. <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />I Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M7) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (Mil <br />Other Violations <br />999 <br />Other: <br />See attached "Continuation — Official Inspection Report' for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS II, or MINOR -Notice to Comply) <br />On site to witness the monitoring system certification testing and perform the routine inspection. <br />201. The L4 diesel annular and L5 87 annular sensors alarmed on February 25, 2013. The designated <br />operator did not document these alarms on the monthly designated operator report nor were they <br />documented on the facility alarm log. These records shall be kept on site for at least 3 years. <br />Immediately locate and maintain the facility alarm log and submit copies to the EHD by February 28, <br />2014. <br />204. The designated operator failed to document all the alarms from the attached alarm history on the <br />March 11, 2013, designated operator monthly inspection report and failed to check that they were <br />responded to appropriately. The missing alarms include: the L4 diesel annular and L5 87 annular <br />sensors which alarmed on February 25, 2013. During the monthly inspection, the designated operator <br />shall review the alarm history for the previous month, check that each alarm was documented and <br />responded to appropriately, and attach a copy of the alarm history with documentation taken in response <br />to any alarms to the monthly report. Ensure that designated operators performing monthly inspections <br />at this facility are including all of the required information on the reports. <br />204. The designated operator failed to check and note the correct test dates for the monitoring system <br />certification, leak detector, and spill container tests on the November 5, 2013 designated operator <br />monthly inspection report. The test date was listed as 1-1-13, but should have been listed as 1-28-13. <br />The designated operator failed to check and note the correct test dates for the monitoring system <br />certification and spill container tests on the June 2013 through October 2013 designated operator <br />monthly inspection reports. The test date was listed as 1-23-13, but should have been listed as 1-28-13. <br />During the monthly inspection, the designated operator shall check that all required testing and <br />maintenance for the UST system have been completed and document the dates they were done. Ensure <br />that designated operator performing monthly inspections at this facility are including all of the required <br />information on the reports. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTIO1 AT ANY TIME AT EH CURRENT HOURLY RATE. <br />