My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 2:49:25 PM
Creation date
6/23/2020 6:46:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.org/ehd <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facility Name: Tesoro Shell #68151 <br />Add�ew 35 N. Cherokee Ln. Lodi CA 95240 <br />inspection <br />t 1O" Jan 28, 2013 <br />VIOLATIONS <br /># <br />C7 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and SafetyCode; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (M1) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (Mi) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />CLASS 1, CLASS 11, or MINOR -Notice to Comply) <br />On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br />106. The monitoring plan on site is not current. The monitoring plan is missing the Red Jacket FX1 V leak <br />detector and the Veeder Root 205 sensor. The monitoring and response plans must be current and <br />approved by the EHD. Complete and submit a copy of the monitoring plan for approval by the EHD by <br />February 28, 2013. An approved copy will be returned for your records. <br />203. Diesel fuel was leaking from the diesel filter inside dispenser #3/4 on January 28, 2013, was not <br />recorded. Any release from the primary containment that does not escape the secondary containment <br />and was cleaned up within eight hours of being detected shall be recorded with the following information: <br />1. Operator's name and phone number <br />2. List of types, quantities, and concentrations of hazardous substances released <br />3. Description of actions taken to control and clean the release <br />4. Method and location of disposal of the released substances <br />5. Description of actions taken to repair and prevent future releases <br />6. Description of method used to reactivate interstitial monitoring after repair or replacement of <br />primary containment <br />Immediately record this release with the information required, and maintain it on site with the facility's <br />monitoring records. Submit a copy of the recordable release statement to the EHD by February 28, <br />2013. <br />305. The sensor in the 91 turbine sump failed to stop the flow of product at the dispenser when tested. <br />All monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of <br />product at the dispenser when it detects a leak. During the inspection, the technician replaced the 91 <br />turbine relay. Positive shutdown of the 91 turbine was verified during the retest of the 91 sensor, sensor <br />out/fail safe and power out functionality tests. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />EHD 23-02 Rev 04/19/12 1 / Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.