My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 2:49:25 PM
Creation date
6/23/2020 6:46:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FEB -25-2011 15:47 Service Station Systems 408 938 8888 P.04 <br />'fest Method Developed By: ❑ Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br />E) Other (Spec) <br />Test Method Used: ❑ Pressure ® Vacuum ❑ Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Test plugs, venturi pump and gauges <br />Tank # 87 Tank 0 89 <br />Equipment Resolution: 0.5% of span <br />Tank # 91 <br />Is Tank Exempt From Testing?' <br />® Yes 0 No ❑ Yes 0 No <br />❑ Yes 0 No <br />Tank Capacity: <br />12k 12k <br />12k <br />Tank Material: <br />Fiberglass Fiberglass <br />Fiberglass <br />Tank Manufacturer: <br />Owens Corning Owens Corning <br />Owens Corning <br />Product Stored: <br />Gasoline Gasoline <br />Gasoline <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />10 rein 10 min <br />10 min <br />Test Start Time: <br />8:30 am 8:30 am <br />11:20 am <br />Initial Reading (R,): <br />7" lig 7" hg <br />7" hg <br />Test End Time: <br />9:30 am 9:30 am <br />12:20 pm <br />Final Reading (RF): <br />7" hg 7" hg <br />7" hg <br />Test Duration: <br />I hour i hour <br />1 hour <br />Change in Reading (RF -RI): <br />None None <br />None <br />Pass/Fail Threshold or Criteria. <br />No Detectable Loss No Detectable Loss <br />No Detectable Loss <br />Test Result: <br />10 Pass Q Fail ® Pass 0 Fail <br />® Pass ❑ Fail <br />Was sensor removed for testing? <br />® Yes ❑ No ❑ NA ® Yes ❑ No ❑ NA <br />® Yes ❑ No ❑ NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />®Yes p No [3 NA ®Yes E] No E] NA <br />®Yes p No ❑ NA <br />Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(x)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.