My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 2:49:25 PM
Creation date
6/23/2020 6:46:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FEB -25-2011 15:48 <br />Service Station Systems <br />Bravo <br />408 938 8888 P.07 <br />bravo <br />UDC Material: <br />Steel <br />Steel <br />7. <br />UNDER -DISPENSER CONTAINMENT UDC <br />TES'T'ING <br />Test Method Developed By: <br />❑ UDC Manufacturer <br />0 industry Standard <br />❑ Professional Engineer <br />° <br />❑ Other (Specify) <br />Bottom <br />Bottom <br />Test Method Used: <br />Q Pressure <br />❑ Vacuum <br />J@ Hydrostatic <br />® Yes ❑ No ®NA <br />❑ Other (Spec) <br />Height from UDC Bottom to <br />Bottom <br />Test Equipment Used: Incon Sump <br />Tester <br />Equipment Resolution: +/- 0.002" <br />Lowest Electrical Penetration: <br />1)n(' 41/2 i inr # 3/4 I1Dr 95/6 I111C_ # 7/R <br />UDC Manufacturer: <br />Bravo <br />Bravo <br />Bravo <br />bravo <br />UDC Material: <br />Steel <br />Steel <br />Steel <br />Steel <br />UDC Depth: <br />12" <br />12" <br />12" <br />12" <br />Height from UDC Bottom to Top <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />of Highest Piping Penetration. <br />❑ yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />® Yes ❑ No ®NA <br />❑ Yes ❑ No 9 NA <br />Height from UDC Bottom to <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />Lowest Electrical Penetration: <br />12:28 pm <br />12:28 pm <br />1:32 m <br />1:32 pm <br />Condition of UDC prior to <br />Good <br />Good <br />Good <br />Good <br />testing: <br />12:43 pm�12:43 <br />pm <br />1:47 pm <br />1:47 pm <br />Portion of UDC Tested' <br />2" above piping <br />2" above piping <br />2" above piping <br />2" above i in <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water).)' <br />❑ Yes ❑ No ® NA <br />❑ Yes ❑ No ONA <br />❑ Yes ❑ No SNA <br />p Yes C3 No ® NA <br />Turbine shutdown re nse time <br />N/A <br />N/A <br />, N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?" <br />® Yes ❑ No N NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />❑ Yes ❑ No ® NA <br />Was fail-safe verified to be <br />op erational?* <br />❑ yes ❑ No ®NA <br />❑ Yes ❑ No ®NA <br />® Yes ❑ No ®NA <br />❑ Yes ❑ No 9 NA <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test <br />30 minutes <br />30 minutes <br />30 minutes <br />30 minutes <br />Test Start Time: <br />12:28 pm <br />12:28 pm <br />1:32 m <br />1:32 pm <br />Initial Reading (Rt): <br />2,1257 <br />2.5268 <br />5.7788 <br />4.2367 <br />Test End Time: <br />12:43 pm�12:43 <br />pm <br />1:47 pm <br />1:47 pm <br />Final Readin F : <br />2.1256 <br />2.5250 <br />5.7781 <br />4.2364 <br />'Gest Duration: <br />15 min <br />13 min <br />15 min <br />15 min <br />Change in Reading (RF -Rt): <br />-0.0001 <br />-0.0018 <br />-0.0007 <br />-0.0003 <br />Pass/Fail Threshold or Criteria: <br />+/_ 0.002" <br />+/- 0.002" <br />+/-0.002" <br />+/-0.002" <br />Test Result: <br />® Pass 0 Fail <br />M Pass ❑ Fail <br />® Pass ❑ Fail <br />0 Pass ❑_ Fail <br />Was sensor removed for tcstin `? <br />❑Yes L3 No p@ NA <br />❑Yes ❑ No ® NA <br />[]Yes ❑ No ® NA <br />❑Yes Q No B NA <br />Was sensor properly replaced and <br />verified functional after tcstin ? <br />❑ Yc 5 ❑ No ®NA <br />L7 Yes ❑ No NA <br />❑Yes ❑ No ®NA <br />❑Yes ❑ No 11 NA <br />Comments -- (include information on repairs made prior to resttMg and recomme►aded follow-i4p,fvr failed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work <br />j If the entire depth of the UDC is not tested, speei Ey how much was tested, if the answer to a_,y of the questions indicated with an <br />asterisk (*) is°` OY or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.