Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br />UNDERGROUND STORAGE TANK <br />MONITORING PLAN — (Page I of 2) <br />TYPE OF ACTION x LNEW PLAN El 1 CHANGE OF INFORMATION 490-1 <br />4 <br />PLAN TYPE? X 1. MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 90-2 <br />(Check one item oniy) C] 2. THIS PLAN COVERS ONLY I'HE FOLLOWING UST SYSTEM(S): <br />I. FACILITY INFORMATION <br />FACILITY ID.4 (Agency b'se On(y) <br />BUSINESS NAME (Same as l-­acih4,Nanre or DBA) USA/Tesoro 68151 <br />BUSINESS SITE ADDRESS ttw <br />35 N. Cherokee Lane CITY Lodi <br />11. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br />preventive maintenance, and calibration of monitoring equipment (e.g.. sensors, probes, line leak detectors, etc.) must be performed at the frequency specified <br />by the equipment manufacturers' instructions, or annual y, whichever is more frequent. Such work must be performed hy qualified persvlmcl, 121 CCR 52631, 2614. '(All <br />_111_111 I - 1111a-1 1.1111, -­­ ­­- ­ ­ __ _. I I 1_1____1 111- 1 <br />II- 4wi <br />MONITORING EQU IPMEN r IS SERVICED X L ANNUALLY El 99 OTHER (Specify): <br />111. MONITORING LOCATIONS <br />❑ L NEW SITE PLOTPLAWMAP SUBMITTED wrrH THIS PLAN (:1 2. SITE PLOT PLANIMAP PREVIOUSLY SUBMITTED 123 CCR §2632,26.1111 4904 <br />( ' 'eck all <br />IV. TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (h <br />that app1j,) <br />1 X I. CONTINUOUS ELECTRON IC TANK MONITORING OF ANNULAR (INTERSTITIAL) SPACE(S) OR SECONDARY CONTAINMENT VAULT(S) <br />WILL I AUDIBLE AND VISUAL ALARMS, [23 CCR §2637, 26341 <br />SECONDARY CONTAINMENT IS: X a, DRY 0 b. LIQUID FILLED C3 c. PRESSI, , 1RIZED 0 d, UNDER VACUUM 490-6 <br />PANEL MANUFACTURER: Gilbarco 4W.7 MODEL. #: EMC 49M <br />4901Q 41-11 <br />LEAK SENSOR MANUFACTURF"R: Veeder Root MODEL #(s): 794390-420 <br />❑ I 1�0fbmxfitfl i KiLLWALLTANKLS'. t23 CCR q.6431 <br />N6 (ATG) SYSTEM USED TO MONITOR alN <br />490-12 MODEL, is. 41K,131 <br />PANEL MANUFACTLIRER: <br />49,M4 MODEL #(S)� asap -15 <br />IN -TANK PROBE MANUFACTURER, <br />LEAK TEST FREQUENCY: [I a, CONTINUOUS ❑ b. DAILY'NIGHTLY ❑ c- WI-L-,KLY <br />490.17 <br />❑ d. MONTHLY ❑ e. OTHER (Specify): <br />ls <br />�i <br />PROGRAMMED TESTS: ❑ a. fl. I g,p.h. C1 b. 0.2 -,P.h� ❑ c. OTHER (Specify).: 4q0- 19 _�o <br />--- <br />[j 3. -MON­THL.Y STAT --- L -S -TICAL IN,V,EN-*T-0R­Y R LCONCILLATION- IZ-3C& §264A 11 <br />4. WFI.',,Kl.,Y MANUAL TANK GAUGING (M TG) t23 CCR §264.51 rESTING PERIOD• ❑ a- 36 HOURS ❑ b. 60 HOURS 490-22, <br />❑431-21 <br />5. TANK INTEGRITY'ri,"sTING PER [23 CCR §264.3 11 490-23490-24 <br />LEST FREQUENCY: Ela. ANNUALLY C3 b. BIENNIALLY 0 c. OTHER (Specify): coo 2s <br />440-26 <br />C1 99.oTHER(Spccifv). 49027 <br />V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Check all <br />X 1, CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S) AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE & VISUAL ALARMS, 460-2g <br />113 CCR SECONDARYCONTAINMENTIS: X a. DRY ❑ b. LIQUID FILLED D c. PRESSURIZED n d. UNDER VACUUM 490-29 <br />§26361 <br />PANEL MANUFACTURER: Gilbarco 490-30 MODEL #: EMC 490.31 <br />LEAK SENSOR MANUFACTURER: Veeder Root 4"'32 MODEL #(s): 794380-208 4oG-33 <br />PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP (i.c.,TURBINE) SHUTDOWN. ❑ a. YES X b, NO 4911-34, <br />FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN ITDOWNFj a. YES X b. NO 4gc s1_ <br />6 -------------- 40- <br />X 2. MECHANICAL LINE LEAK DETECTOR (MLLD) THAT ROUTINELY PERFORMS 3.0 g,p,h. LEAK TESTS AND RESTRICTS OR SHTJTS OFF 9 <br />PRODUCT FLOW WHEN A LEAK IS DETECTED. 123 CCR§126361 <br />MLLD MANUFACTURER(S): Vaporless 490-3 7 MODEL #(s): L 200 . ..... 49'3-39 <br />C1 3. ELECTRONIC LINE LEAK DETECTOR (ELLD) THAT ROUTINELY PERFORMS 3.0 g,pJiLEAK TESTS. [2-3 CCR§26361 <br />ELLD MANUFACTURER(S): 4W-40 MODEL e(S): 41,1941 <br />490-4 <br />PROGRAMMED IN LANE LEAK TEST: C1 a. MINIMUM MONTHLY 0.2 g-lp,h, 0 b. MINIMUM ANNUAL 0.1 g,p,h. <br />190-42 <br />3 <br />ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. 0 a. YES C1 b. NO <br />ELLD FAILUREIDISCONNE(7rlON'I'RIGCjERS AUTOMATIC PUMP SHUTDOWN, [I a. YES E] b. No 4110-44 <br />❑ �904 5 <br />4, PIPE INTEGRITYTESTING, <br />490-46 <br />TEST FREQUENCY: ❑ a. ANNUALLY ❑ b. EVERY 3 YEARS [I c. OTHER (Specify) 490-47 <br />490-48 <br />❑ 5. VISUAL PIPE MONITORING. <br />FREQUENCY: ❑ a. DAILY ❑ b. WEEKLY 0 C. MIN, MONTHLY & EACH TIME SYSTEM OPERATED, 490-49 <br />AinejfiKmnil ring 9(9-bu _PjPpg only, PeJ�s 5^ <br />. ............ ..... ....... . . . 490-;0, <br />❑ 6. SUCTION PIPING MEETS EXEMPTION CRITERIA. (23 CCR §63,6oQl3)j .. . .. ..... ....... <br />C]7 NO REGULATED PIPING PER HEALTH AND SAFETY CODE, DIVISION 20, CHAPTER 6.7 IS CONNECTEDTOTHE TANK SYS TENT 490-il <br />0 99. OTHER (Specify) 490-11_ <br />UPCF UST -D (12/2007) - 115 www.unidoes.org <br />