Laserfiche WebLink
0 aE&ivEr; <br />Monitoring System Certification - Page 3 or 3 <br />MMEM <br />Site Address: 35 N. Cherokee Ln. ROW&3"T,#[rg: 1/28/16 <br />F. In - Tank Gauging / SIR Equipment: N Check this box if tank gauging is used only for inventory control, <br />0 Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />Camnlete the following checklist. <br />0 Yes <br />0 No* <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />0 Yes <br />0 No* <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />0 Yes <br />a No* <br />Was accuracy of system product level readings tested? <br />0 Yes <br />0 No* <br />Was accuracy of system water level readings tested? <br />0 Yes <br />0 No* <br />Were all probes reinstalled properly? <br />0 Yes <br />0 No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />In Section H below, describe how and when these deficiencies were or will be corrected. <br />G. Line Leak Detectors (LLD): 0 Check this box if LLD's are not installed. <br />Camnlete the following checklist-. <br />CC Yes <br />0 No* <br />For equipment start-up or annual equipment certification was a leak simulated to verify LLD performance? <br />0 N/A <br />(Check all that aj)plv) Simulated leak rate: a 3 g.p.h. (1.); 0 0.1 g.p.h. (2.); 0 0.2 g.p.h. (2.). <br />Notes: 1. Required for equipment start-up certification A_nd annual certification. <br />2. Unless mandated bX local agency, certification required only for electronic LLD start-up. <br />0 Yes <br />0 No* <br />Were all LLD's confirmed operational and accurate within reEulatory requirements? <br />0 Yes <br />0 No* <br />Was the testing a2paratus properly calibrated? <br />0 Yes <br />0 No* <br />For mechanical LLD's, does the LLD restrict product flow if it detects 1 leak? <br />0 N/A <br />Q Yes <br />0 No* <br />For electronic LLD's, does the turbine automatically shut off if the LLD detects a leak? <br />cc N/A <br />0 Yes <br />0 No* <br />For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system is disabled <br />2 NIA <br />or disconnected? <br />0 Yes <br />0 No* <br />For electronic LLD's, does the turbine automatically shut off if any portion of the monitoring system <br />0 N/A <br />malfunctions or fails a test? <br />0 Yes <br />0 No* <br />For electronic LLD's, have all accessible wiring connections been visually inspected? <br />0 N/A <br />H Yes <br />0 No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />In Section H below, describe how and when these deficiencies were or will be corrected. <br />H. Comments: <br />