My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 2:49:25 PM
Creation date
6/23/2020 6:46:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Test Method Developed By: 0 Tank Manufacturer 0 Industry Standard 0 Professional Engineer <br />[I Other (Specify) <br />Test Method Used: E3 Pressure 0 Vacuum 0 Hydrostatic <br />[I Other (Specify) <br />"Test Equipment Used: Test plugs, venturi pump and gauges Equipment Resolution: 0.5% of span <br />Is Tank Exempt From Testing?' <br />Tank Capacity: <br />Tank Material: <br />Tank Manufacturer: <br />Product Stored: <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: <br />Initial Reading (Rj): <br />Test End Time: <br />Final Reading (RF): <br />Test Duration: <br />Change in Reading (RF-Rj): <br />Pass/Fail Threshold or Criteria: <br />Test Result: <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testinL. <br />Tank # 87 <br />0yes 0 No <br />l2k <br />Fiberglass <br />Owens Coming <br />Gasoline <br />7:45 am <br />7" hg <br />8:45 am <br />7" hg <br />I hour <br />None <br />No detectable loss <br />191 Pass 0 Fail <br />0 Yes 0 No El NA <br />Tank # 91 <br />[]Yes Z No <br />l2k <br />Fiberglass <br />Owens Coming <br />Gasoline <br />10 mill. <br />8:30 am <br />7" hg <br />9:30 am <br />7" hg <br />I hour <br />None <br />No detectable loss <br />0 Pass 0 Fail <br />0 Yes 0 No 0 NA <br />OYes 0 No rl NA <br />Tank# Diesel <br />0Yes 0 No <br />l2k <br />Fiberglass <br />Owens Coming <br />Diesel <br />10 min. <br />8:45 am <br />7" hg <br />9:45 am <br />7" hg <br />I hour <br />None <br />No detectable loss <br />0 Pass 0 Fail <br />0 Yes n No ONA <br />BYes; 0 No 0 NA <br />Comments — (include!rLormarion on re airs made prior to testing, and recommended follou-upforfailed tests) <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />1 Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. fCalifomia Code of Regulations, Title 23, Section 2637(a)(6)) <br />