My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CHEROKEE
>
35
>
2300 - Underground Storage Tank Program
>
PR0231320
>
COMPLIANCE INFO_2009-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/8/2022 2:49:25 PM
Creation date
6/23/2020 6:46:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2015
RECORD_ID
PR0231320
PE
2361
FACILITY_ID
FA0003602
FACILITY_NAME
TESORO (SPEEDWAY) 68151
STREET_NUMBER
35
Direction
N
STREET_NAME
CHEROKEE
STREET_TYPE
LN
City
LODI
Zip
95240
APN
04318003
CURRENT_STATUS
01
SITE_LOCATION
35 N CHEROKEE LN
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231320_35 N CHEROKEE_2009-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
453
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Test Method Developed By: <br />t Test Method Used: <br />I Test Equipment Used: Incon <br />Sump Diameter: <br />Sump Depth: <br />Sump Material: <br />Height from Tank Top to Top of <br />Hi hest Piping Penetration: <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />Condition of sump prior to testing: <br />Portion of Sump Tested' <br />Does turbine shut down when <br />sump sensor detects liquid (both <br />product and water)?* <br />Turbine shutdown response time <br />Is system programmed for fail <br />shutdown?* <br />Was fail-safe verified —to be <br />o crational?* <br />Wait time between applying <br />pressure/vacuum/water and starting <br />test: <br />Test Start Time: <br />Initial Reading (Ri): <br />Test End Time: <br />Final Reading (RO: <br />Test Duration: <br />Change in Reading (RF-Ri): <br />Pass/Fai I Threshold or Criteria: <br />Test Result - <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />verified functional after testine, — <br />M, a 14 twL rMl #KVJ 19 <br />[] Sump Manufacturer <br />[I Other (Specify) <br />[] Pressure <br />0 Other (Specify) <br />Tester <br />STP Sump # 87 <br />42" <br />68" <br />Fiberglass <br />2411 <br />12" <br />Good <br />2" above piping <br />30 minutes <br />9:54 am <br />4.6377 <br />10:09 am <br />15 min. <br />0.0003 <br />0.002" <br />[ _Pass 0 Fail <br />0 Yes 0 No E] NA <br />OYesONoONA <br />Industry Standard 0 Professional Engineer <br />Vacuum 0 Hydrostatic <br />I Equipment Resolution: +/- 0.002" <br />STP Sumv # 91 <br />42" <br />68" <br />Fiberglass <br />12" <br />MWIMMIJ,SII 11911M <br />x �u <br />30 minutes <br />9:54 am <br />3.8751 <br />10:09 am <br />—3.050 <br />15 min. <br />0.0001 <br />+/-0100211 <br />Pass 0 Fail <br />0 Yes El No 0 NA <br />0 Yes 0 No 0 NA <br />STP Sump # Diesel <br />42" <br />61" <br />Fiberglass <br />12" <br />N/A <br />n Yes El No 0 NA <br />30 minutes <br />9:54 am <br />3.4190 <br />10:09 am <br />3.4198 <br />15 min. <br />0.0008 <br />+/_ 0.002" <br />0 Pass 0 Fail <br />0 Yes El No 0 NA <br />OYes E] No 0 NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-!Pforfailed lav!s2 <br />"Sensor functionality was not confirmed. This procedure is not part of the Secondary Containment testing scope of work". <br />1 If the entire depth of the sump is not tested, specify how much was tested. If the answer to any of the questions indicated with an <br />asterisk(*) is "NO" or "NA", the entire sump must be tested. (See SWRCBLO-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.