JUN-16-2010 09:10 Service Station Systems 408 938 8888 P.08 <br /> 0 <br /> UNDER-DISPENSER CONTAINMENT aq TESTING <br /> Test Method Developed By: Ej UDC Manufacturer J@ Industry Standard [j Professional Engineer <br /> 0 Other(Specify) <br /> Test Method Used: 0 Pressure E] Vacuum 0 Hydrostatic <br /> El Other(Specify) <br /> Test Equipment Used: Incon Sump Tester Equipment Resolution: +/-0.002" <br /> WNW MEMEMIZEEM" <br /> UDC#97/1-0 UDC#11/12 UDC 9 13/14 UDC# IS/16 <br /> UDC Manufacturer: OPW OPW OPW OPW <br /> UDC Material: Plastic Plastic Plastic Plastic <br /> UDC Dc !h31" 31" 311, 31$9 <br /> l? <br /> Height from UDC Bottom to Top 14" 14" 14" 14" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 14" 14" 1471 14" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to Good Good Good Good <br /> testing: <br /> Portion of UDC Tested2"above pi ins 2"above piping 211 above piping 2"above R!ntL__ <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both 0 Yes 0 No 0 NA El Yes 0 No IONA [3 Yes Ej No ONA 0 Yes[3 No ONA <br /> product and water <br /> Turbine shutdown resporme time N/A N/A N/A N/A <br /> Is system programmed for fail- El Yes El No 0 NA []Yes[I No ONA [3 Yes[:]No ONA []Yes[3 No ONA <br /> safe shutdown?' <br /> Was fail-safe verified to be 0 Yes 0 No 0 NA Cj Yes[I No ONA E)Yes jj No ONA [3 Yes El No RNA <br /> o2er4.+.onal?' <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test <br /> Test Start Time: 3:46 pm 3:13 2m 4:27 pm 2:35 pm <br /> Initial 1 3.1400 3,5156 5.4058 5.6195 <br /> Test End Time: 4:01 In 3:28 p!n_ 4:42 prn 2:50 pm <br /> Final Reading(RF): 3.1400 3.5154 5,4000 5,6212 <br /> Test Duration. 15 min. 15 min. 15 min. 15 min. <br /> ChLng in Readin&(RrR,): None -0.0002 +0.0002 +0.0017 <br /> Pass/Fail Threshold or Criteria. +/_0.002" +/-0.002" +/-0.002" +/-0.002" <br /> Test Result: El Pass 0 Fail El Pass 0 Fall 23 Pam 0 Fail M Pass 0 Fail <br /> Was sensor removed for testing? 0 Yes[3 No [3 NA 0 Yes E]No 0 NA 0 Yes Q No EINA 0 Yes 0 No <br /> Was sensor properly replaced and ® Yes[3 No [3 NA 0 Yes E)No [3 NA 0 Yes Cj No (:JNA 0 Yes 0 No DNA <br /> verified functional after testing? <br /> Comments—(include information on re airs made prior to testing, and recommended follow-up for failed teals) <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br /> 1 If the entire depth of the UDC is not tested,specify how much was testetd. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />