Laserfiche WebLink
JUN-16-2010 09:10 Service Station Systems 408 938 8888 P.09 <br /> 4 <br /> 9. FILL RISER CONTAINMENT SUMP TESTING <br /> Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br /> Fill Riser Containment Sumps are Present,but were Not Vested ❑ <br /> Test Method Developed By: ❑ Sump Manufacturer ®Industry Standard ❑ Professional Engineer <br /> ❑lather(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: lncon Sump Tester Equipment Resolution: +/-0.002" <br /> M, NlMG: AN <br /> Fill Sump#87 Fill Sume#84 Fill Sum #91 Fill Sumg#f Diesel <br /> Sump Diameter: 42" 42" 42" 42" <br /> Sump Depth: 60" 60" 60" 60" <br /> Height from Tanis Top to Top of N/A N/A N/A N/A <br /> Highest Piping Penetration: <br /> Height from Tank Top to Lowest 26" 26" 26" 26" <br /> Electrical Penetration: <br /> Condition of sump prior to Good Good Good Good <br /> testing: <br /> Portion of Sum2 Tested 2"above piping 2"above piping 2"above i in 2"above piping <br /> S!lm2 Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> s=ing test: <br /> Test Start Time: 9:33 am 9:56 am 9:06 am 9:33 am <br /> Initial Reading(R,): 4.6070 6,2358 5.9014 5.4652 <br /> Test End Time: 9:48 am 10:12 am 9:21 am 9:48 am <br /> Final Reading(RF): 4.6072 6.2355 5.9021 5.4649 <br /> Test Duration: 15 min. 16 min. 15 min. 15 min. <br /> Chan a in Reading RF-Rt : +0.0002 -0.0003 +0.0007 -0.0003 <br /> Pass/Fail Threshold or Criteria: +/-01002" +/-O.M" +/-0.002" +/-0.002" <br /> Test Result: ® Pass ❑.IFail 3 Pass ❑Fail ® Pass 0 Fail ® Pass 0.Fall <br /> is there a sensor in the sump? , ® Yes ❑No 0 Yes ❑No ® Yes ❑No ® Yes ❑No <br /> Does the sensor alarm when <br /> either product or water is ❑ Yes❑No M NA ❑Yes❑No ®NA ❑Yes❑No ONA ❑Yes❑No ®NA <br /> detected? <br /> Was sensor removed for testin ? ® Yes❑No ❑NA ®Yes EJ No ❑NA ®Yes❑No ❑NA ®Yes[3 No ❑NA <br /> Was sensor property replaced and ®Yes❑No ❑NA ®Yes❑No [INA ®Yes E3 No [JNA ® Yes❑No ❑NA <br /> verified functional after testing? <br /> Comments-- (include information on repairs made prior to testing, and recommended follow-u forfailed tests) <br /> "Sensor functionality was not confirmed.This procedure is not part of the Secondary Containment testing scope of work". <br />