My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1987-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2022 1:58:10 PM
Creation date
6/23/2020 6:47:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1998
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1987-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
What threshold value f(tduct volume change (gallon per hour) is used to declare that <br />a tank is leaking? <br />(X ) 0.05 gallon per hour <br />O 0.10 gallon per hour <br />0.20 gallon per hour <br />other (list) <br />Under what conditions are test results considered inconclusive? <br />(X) too much variability in the data (standard deviation beyond a given value) <br />unexplained product volume increase <br />other (describe briefly) <br />Exceptions <br />Are there any conditions under which a test should not be conducted? <br />water in the excavation zone <br />large difference between ground temperature and delivered product temperature <br />extremely high or low ambient temperature <br />invalid for some products (specify) <br />(X ) other (describe briefly) none <br />What are acceptable deviations from the standard testing protocol? <br />O none <br />lengthen the duration of test <br />(X ) other (describe briefly) Repeat test until consistent results are obtained. <br />What elements of the test procedure are determined by personnel on-site? <br />product level when test is conducted <br />when to conduct test <br />waiting period between filling tank and beginning test <br />length of test <br />determination that tank deformation has subsided <br />determination of "outlier" data that may be discarded <br />other (describe briefly) <br />Kl=i. <br />ATGS - Description Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.