FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1987-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Results oi ij.S. LP" d L4 uativa <br />Voluetric TankTightness .' 1 d <br />This form tells whether the tank tightness testing method described below complies with the performance <br />requirements of the federal underground storage tank regulation. The evaluation was conducted by the <br />equipment manufacturer or a consultant to the manufacturer according to the U.S. EPA's "Standard Test <br />Procedure for Evaluating Leak Detection Methods: Volumetric Tank Tightness Testing Methods." The full <br />evaluation report also includes a form describing the method and a form summarizing the test data. <br />Tank owners using this leak detection system should keep this form on file to provide compliance with the <br />federal regulations. Tank owners should check with State and local agencies to make sure this form satisfies <br />their requirements. <br />Method Description <br />- Name Tidel Environmental Monitoring System <br />Vendor Tidel Engineering, <br />i-BettlineRoad <br />Carrollton, Texas -75006 a 416-82 <br />Evaluation Results <br />This method which declares a tank to be leaking when the measured leak rate exceeds the <br />threshold of 0.05 gallon per hour, has a probability of false alarms [P(FA)] of 4.67 %. <br />The corresponding probability of detection [P(D)] of a 0.10 gallon per hour leak is 95.33 %. <br />Therefore, this method ()Q does ( ) does not meet the federal performance standards <br />established by the U.S. Environmental Protection Agency (0.10 gallon per hour at P(D) of <br />95% and P(FA) of 5%). <br />The evaluation testing was conducted in a 10.000 gallon (?) steel O fiberglass tank <br />that was 96 inches in diameter and 324 inches long. <br />The tests were conducted with the tank product levels 50 to 90 percent full. <br />The temperature difference between product added to fill the tank and product <br />already in the tank ranged from -5.33 deg F to +5.35 deg F, <br />with a standard deviation of 4.25 deg F. <br />The product used in the evaluation was unleaded gasoline <br />Volumetric TrT Method - Resutts Form Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.