My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1987-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2022 1:58:10 PM
Creation date
6/23/2020 6:47:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1998
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1987-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sensitivity ITrapped Vapor <br />14. (X) According to the vendor, this system can be used even if trapped vapor is present in the <br />pipeline during a test. <br />( ) According to the vendor, this system should not be used if trapped vapor is present in <br />the pipeline. <br />15. The sensitivity of this system to trapped vapor is indicated by the test results summarized in <br />Table 2. These tests were conducted at operating psi with 110 ml of vapor trapped <br />in the line at a pressure of 0 psi. The data and test conditions are reported in Attachment 6. <br />Table 2. Summary of the Results of Trapped Vapor Tests <br />Test No. <br />AT <br />M <br />Induced Leak Rate <br />(gal/h @ 20 ps) <br />Measured Leak Rate <br />(leakltight) <br />V-1 <br />+2.96 <br />0 <br />t <br />V-2 <br />+3.94 <br />0.201 <br />leak <br />V-3 <br />+4.69 <br />0301 <br />leak <br />Performance Characteristics of t <br />:ei rr r re Instrumentation <br />16. State below the performance characteristics of the primary measurement system used to <br />collect the data. (Please specify the units, for example, gallons, inches.) <br />Quantity Measured: pressure (psi <br />Resolution: 0.1 psi <br />Precision: 0.1 psi <br />Accuracy: +/- 2% <br />Minimum Detectable Quantity: 0.1 psi <br />Response Time: 1 second <br />Threshold is exceeded when the flow rate due to a leak exceeds 0.2 gal/h. <br />Application of !,. System <br />17. This leak detection system is intended to test pipeline systems that are associated with <br />underground storage tank facilities, that contain petroleum or other chemical products, that <br />are typically constructed of fiberglass or steel, and that typically measure 2 or 3 in. in <br />diameter and 150 ft or less in length. The performance estimates are valid when: <br />• the system that was evaluated has not been substantially changed by subsequent <br />modifications <br />• the manufacturer's instructions for using the system are followed <br />• the mechanical line leak detector <br />( ) ,is present in <br />(X) has been removed from <br />the pipeline (check both if appropriate) <br />the waiting time between the last delivery r ' product t• the underground <br />and the start of data collection for <br />Pipeline Leak Detection System • Results Form Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.