My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1987-1998
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1987-1998
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/18/2022 1:58:10 PM
Creation date
6/23/2020 6:47:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1987-1998
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1987-1998.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
387
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />• <br />4. What is the nominal diam ter of a pipeline that can be tested with this system? <br />( ) 1 in. or Iess <br />(I) between 1 and 3 in. <br />(X) between 3 and 6 in. Contact manufacturer for application to lines greater am 3 in. <br />( ) between 6 and 10 in. <br />( ) other <br />S. The system can be used on pipelines pressurized to 30 psi. <br />The safe maximum operating pressure for this system is 60 psi. <br />6. Does the system conduct a test while a mechanical line leak detector is in place in the <br />pipeline? <br />() yes ( no <br />General Features of the System <br />7. What type of test is the system conducting? (Check all applicable responses.) <br />( ) 0.1 gal/h Line Tightness Test <br />(X} 0.2 gal/h Monthly Monitoring Test <br />(X) 3 gal/h Hourly Test <br />8. Is the system permanently installed on the pipeline? <br />(X? yes ( ) no <br />Does the system test the line automatically? <br />( yes ( ) no <br />If a leak is declared, what does the system do? (Check all applicable responses.) <br />(X) displays or prints a message <br />(X) triggers an alarm <br />(X) alerts the operator <br />(� shuts down the dispensing system <br />9. What quantity or quantities are measured by the system? (Please list.) <br />_pressure (osi) and time <br />10. Does the system use a preset threshold that is automatically activated or that automatically <br />turns on an alarm? <br />yes (If yes, skip question 11.) <br />no (If no, answer question 11.) <br />11. Does the system measure and report the quantity? <br />no <br />Description ,, Detection System Page 2 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.