My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2011
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_1999-2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/23/2024 1:10:52 PM
Creation date
6/23/2020 6:47:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2011
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_1999-2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
513
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`SWRCB, January 2002 <br />0 <br />C <br />S. FILL RISER CONTAINMENT SUMP <br />Page 6 of 7 <br />Facility is Not Equipped With Fill Riser Containment Sumps ❑ <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ® Industry Standard ❑ Professional Engineer <br />❑ Other (Specify) <br />Test Method Uses: ❑Pressure ❑ Vacuum ® Hydrostatic <br />❑ Other (Specify) <br />Test Equipment Used: Incon TS -STS SUMP TESTING SYSTEM Equipment Resolution: 0.001 in. <br />Fill Sump # 1 Fill Sump 0 Fill Sump # Fill Sump # <br />Sump Diameter: 36" <br />Sump Depth: 45" <br />Height from Tank Top to Top of <br />Highest Piping Penetration 16" <br />Height from Tank Top to Lowest <br />Electrical Penetration: 17" <br />Condition of sump prior to <br />testing: GOOD <br />Portion of Sump Tested 19" <br />Sump Material: FIBERGLASS <br />Wait time between= <br />pressure/vacuum/water and <br />starting test: 30 MIN. <br />Test Start Time: 12:23 PM/12:54 PM <br />Initial Reading (R): 4.8434"/4.8425" <br />Test End Time. 12:38 PM/1:09 PM <br />Final Reading (Rf): 4.8440"/4.8419" <br />Test Duration: 2X15 MIN. <br />Change in Reading (Rf-Rj): -0.0006" <br />Pass/Fail Threshold or Criteria: 0.002" <br />Test Result: PASS <br />Is there a sensor in the sump? YES <br />Does the sensor alarm when <br />either product or water is <br />detected? YES <br />Was sensor removed for testing? <br />YES <br />Was sensor properly replaced an <br />verified functional after testing? YES <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Revision: <br />
The URL can be used to link to this page
Your browser does not support the video tag.