My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:36:41 PM
Creation date
6/23/2020 6:47:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
May 8, 2015 <br />Mark Crisp <br />P.0 Inc <br />P.O. Box <br />Nipomo, CA 93444 <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue <br />Stockton, California 95205-6232 <br />Website: www.sjgov.org/ehd <br />Phone: (209) 468-3420 <br />Fax: (209) 464-0138 <br />Re: Verizon California Inc, 430 W Center Street, Manteca <br />FILE COPY <br />DIRECTOR <br />Linda Turkatte, REHS <br />PROGRAM COORDINATORS <br />Robert McClellon, REHS <br />Jeff Carruesco, RENS, RDI <br />Kasey Foley, REHS <br />Rodney Estrada, REHS <br />Adrienne Ellsaesser, REHS <br />SR0071950 <br />The San Joaquin County Environmental Health Department (EHD) has reviewed the submitted <br />plans to replace the existing generator and the day tank, reconstruct the existing piping <br />vault/trench and install the new piping vault, and to remove the existing fuel polisher and the fuel <br />line between the polisher and the underground storage tank at the above referenced address. <br />In order for this permit application review to continue, additional information/clarification <br />must be submitted: <br />1. According to Exhibit A (Paragraph 8),submitted with this permit application, 7...j there is <br />an existing fuel polisher (filter) that has not been in use for many years. This equipment <br />o: will be removed and the fuel line between it and. the underground fuel tank will be <br />removed." The existing site plan, provided to the Environmental Health Department <br />(EHD) by SunWest on 9-22-2010 (attached hereto), illustrates the product line in <br />question leading from the existing fuel polisher to the underground storage tank (UST) <br />sump. According to the email correspondence, received from P.0 Inc on 5-7-2015, P.0 <br />Inc. will be "removing the associated piping with the fuel polisher". Please provide a <br />detailed site drawing illustrating which underground lines will be removed and which will <br />be left in place, also provide a detailed description of how these underground fuel line(s) <br />and any associated sump penetrations will be removed, maintaining the integrity of the <br />existing UST system. <br />2. Please provide cut sheets and the third party approval (engineering specification <br />approved by a -state registered professional engineer) or nationally recognized industry <br />code or engineering standard (Title 23, CCR 2631(d)) for the "new fuel pipe fault" <br />identified on drawing A-2 (Partial Plot Plan -New Work). <br />3. Please clarify what make and model of sump penetrations will be utilized for the supply <br />and return lines inside the proposed "new fuel pipe fault and metal cover", identified on <br />page A-2 of the provided drawings. Provide cut sheets and the third party approval <br />(engineering specification approved by a state registered professional engineer) or <br />nationally recognized industry code or engineering standard (Title 23, CCR 2631(d)) for <br />the proposed penetrations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.