My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2017
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CENTER
>
430
>
2300 - Underground Storage Tank Program
>
PR0231425
>
COMPLIANCE INFO_2012-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 3:36:41 PM
Creation date
6/23/2020 6:47:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2017
RECORD_ID
PR0231425
PE
2361
FACILITY_ID
FA0003838
FACILITY_NAME
Frontier California Inc.: Manteca CO
STREET_NUMBER
430
Direction
W
STREET_NAME
CENTER
STREET_TYPE
St
City
Manteca
Zip
95336
APN
217-021-04
CURRENT_STATUS
01
SITE_LOCATION
430 W Center St
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231425_430 W CENTER_2012-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
530
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />Revision: <br />0 0 <br />SWRCB, January 2002 <br />Page 2 of 7 <br />4. TANK ANNULAR TESTING <br />Test Method Developed By: <br />E3 Tank Manufacturer ® Industry Standard ®Professional Engineer <br />13 Other (spec) <br />Test Method Uses: <br />®Pressure ® Vacuum 13Hydrostatic <br />Other (spec) <br />Test Equipment Used: 0 TO 30" HG. GLYCERIN FILLED VACUUM GUAGES Equipment Resolution: 0.1" HG. <br />MTank <br /># 1 Tank # <br />Tank # <br />Tank # <br />Is tank Exempt From Testing? <br />NO <br />Tank Capacity: <br />6,000 GAL. <br />Tank Material: <br />kTEEL/FIBERGLASS <br />Tank Manufacturer: <br />DOOR <br />20!4 <br />Product Stored: <br />DIESEL <br />Wait time between applying <br />D <br />E-PARTMENT <br />pressure/vacuum/water and starting <br />30 MIN. <br />test: <br />Test Start Time: <br />11:00 AM <br />Initial Reading (R�: <br />10" HG. <br />Test End Time: <br />12:00 PM <br />Final Reading (RF): <br />10" HG. <br />Test Duration: <br />1 HOUR <br />Change in Reading (RF-RI): <br />0 <br />Pass/FaiI Threshold or Criteria: <br />0 <br />YES <br />Was sensor removed for testing? <br />Was sensor properly replaced and <br />YES <br />verified functional after testing? <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />'Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. {California Code of Regulations, Title 23, Section 2637(a)(6)) <br />Revision: <br />
The URL can be used to link to this page
Your browser does not support the video tag.